Measurement of microvascular blood flow in cancellous bone using laser Doppler flowmetry and 133Xe-clearance.

S Hellem, L S Jacobsson, G E Nilsson, D H Lewis.   

Abstract

Blood flow in cancellous bone with varying vascular density was investigated simultaneously with Laser Doppler Flowmetry (LDF) and 133Xe-clearance. The cancellous bone subapical to 2 contralateral incisors in the mandibles of 17 young pigs was used as an experimental model. Light from a 2 mW He-Ne-laser was guided through an optical fibre to a flowmeter probe. Stainless steel probe-holders firmly inserted in the pulpal canals of the two incisors served as the probe entrance to cancellous bone for blood flow recording. Due to the Doppler effect, the light scattered by circulating blood cells undergoes a frequency shift. The back-scattered light picked up by optical fibres in the probe, was guided to a photosensitive device, where it was demodulated. After signal processing, a signal referred to as the Blood Flow Value (BFV) was recorded on a pen recorder. Rhythmical variations (vasomotion) in BFV with frequencies from 2-11 cycles/min were observed in 6% of recordings made initially after probe-holder implantation, and in 34% of the recordings made 5 weeks later. On this occasion, a marked increase in BFV was recorded. Histological examination showed increased vascularity in the bone tissue. The reproducibility error of LDF was 7.4% and temporal changes in BFV, apart from vasomotion, were 8.3%, provided no injections or manipulations of the probe were made. Spatial variations in BFV were found to be related to the vascular density. 2 successive recordings by LDF from the same bone area were highly correlated (r = 0.98). The corresponding figure for 2 logarithmic decay rates of locally injected 133Xe was 0.76. No correlation between BFV and 133Xe-clearance could be demonstrated.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6224749     DOI: 10.1016/s0300-9785(83)80063-5

Source DB:  PubMed          Journal:  Int J Oral Surg        ISSN: 0300-9785


  11 in total

1.  An in-vitro analysis of two laser Doppler flowmetry systems for evaluation of bone perfusion.

Authors:  G K Carpenter; M F Swiontkowski
Journal:  Calcif Tissue Int       Date:  1991-06       Impact factor: 4.333

2.  Evaluation of a laser Doppler flowmetry implantable fiber system for determination of threshold thickness for flow detection in bone.

Authors:  E H Schemitsch; M J Kowalski; M F Swiontkowski
Journal:  Calcif Tissue Int       Date:  1994-09       Impact factor: 4.333

3.  Diffuse Optics for Tissue Monitoring and Tomography.

Authors:  T Durduran; R Choe; W B Baker; A G Yodh
Journal:  Rep Prog Phys       Date:  2010-07

4.  Comparison of two laser Doppler flowmetry systems for bone blood flow analysis.

Authors:  M F Swiontkowski; F Schlehr; J C Collins; R Sanders; A Pou
Journal:  Calcif Tissue Int       Date:  1988-08       Impact factor: 4.333

5.  Integrating probe for tissue laser Doppler flowmeters.

Authors:  E G Salerud; G E Nilsson
Journal:  Med Biol Eng Comput       Date:  1986-07       Impact factor: 2.602

6.  In vivo monitoring of circulation in the intact anterior cruciate ligament using the laser Doppler flowmeter.

Authors:  J M Passler; R Wildburger; H P Hofer; M Fellinger
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  1993       Impact factor: 4.342

7.  Assessment of the relationship between standard probe and implantable fiber measurements of cortical bone blood flow: a canine study.

Authors:  R Jain; N Podworny; G I Anderson; E H Schemitsch
Journal:  Calcif Tissue Int       Date:  1996-07       Impact factor: 4.333

8.  Quantification and characterization of radiation-induced changes to mandibular vascularity using micro-computed tomography.

Authors:  Sagar Satish Deshpande; Alexis Donneys; Aaron Samuel Farberg; Catherine N Tchanque-Fossuo; Peter A Felice; Steven Richard Buchman
Journal:  Ann Plast Surg       Date:  2014-01       Impact factor: 1.539

9.  The effect of blood flow on the material properties of bone.

Authors:  F McDonald; T R Pitt Ford
Journal:  Ann Biomed Eng       Date:  1994 Mar-Apr       Impact factor: 3.934

10.  Pilot Study of Laser Doppler Measurement of Flow Variability in the Microcirculation of the Palatal Mucosa.

Authors:  Pierre Le Bars; Gaston Niagha; Ayepa Alain Kouadio; Julien Demoersman; Elisabeth Roy; Valérie Armengol; Assem Soueidan
Journal:  Biomed Res Int       Date:  2016-06-01       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.