Comparison of two laser Doppler flowmetry systems for bone blood flow analysis.

M F Swiontkowski1, F Schlehr, J C Collins, R Sanders, A Pou.   

Abstract

The development of laser Doppler flowmetry (LDF) has provided a real-time, reliable method for monitoring capillary perfusion in multiple tissues. LDF has potential for the experimental and clinical assessment of bone blood flow. To compare the accuracy and ease of use of two commercially available laser Doppler flowmeters with different mechanisms for processing the Doppler-shifted component of light, estimates of bone blood flow were obtained in a sheep model using the two systems, and the values derived then compared with estimates of bone blood flow also obtained in a sheep using the technique of injection of labeled microspheres. The single-channel laser Doppler flowmeter, the LD 5000, processes the reference and Doppler-shifted beams on the surface of a single photodetector using optical heterodyning for measurement. The dual-channel flowmeter, the Periflux 2, uses two optical fibers to transmit reference and Doppler-shifted light to two separate photodetectors. The differential amplification and detection system improves the signal-to-noise ratio. Measurement of both metaphyseal (cancellous) and diaphyseal (cortical) blood flow using both LDF systems was compared with values obtained with an injection of 85Sr-labeled microspheres in three sheep. The LDF measurements were repeated after occlusion of the left femoral artery, and a 46Sc microsphere injection was performed prior to animal sacrifice. Two of the animals developed vasomotor instability, resulting in poor correlation between the measurements obtained with the Periflux 2, which is motion sensitive, and the values obtained with the microsphere method. High correlation was apparent in two of the three animals for the LD 5000 and the microsphere values.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1988        PMID: 3056598     DOI: 10.1007/bf02555155

Source DB:  PubMed          Journal:  Calcif Tissue Int        ISSN: 0171-967X            Impact factor:   4.333


  20 in total

1.  EXTRACTION RATIO AND BONE CLEARANCE OF SR85 AS A MEASURE OF EFFECTIVE BONE BLOOD FLOW.

Authors:  D H COPP; S S SHIM
Journal:  Circ Res       Date:  1965-05       Impact factor: 17.367

2.  Laser Doppler measurements of blood flow in capillary tubes and retinal arteries.

Authors:  C Riva; B Ross; G B Benedek
Journal:  Invest Ophthalmol       Date:  1972-11

Review 3.  Fundamental concepts in bone-blood flow studies.

Authors:  W J Kane
Journal:  J Bone Joint Surg Am       Date:  1968-06       Impact factor: 5.284

4.  Some sources of error in measuring regional blood flow with radioactive microspheres.

Authors:  G D Buckberg; J C Luck; D B Payne; J I Hoffman; J P Archie; D E Fixler
Journal:  J Appl Physiol       Date:  1971-10       Impact factor: 3.531

5.  Determination of cortical blood flow in rabbit femur by radioactive microspheres.

Authors:  P K Lunde; K Michelsen
Journal:  Acta Physiol Scand       Date:  1970-09

6.  Continuous measurement of tissue blood flow by laser-Doppler spectroscopy.

Authors:  M D Stern; D L Lappe; P D Bowen; J E Chimosky; G A Holloway; H R Keiser; R L Bowman
Journal:  Am J Physiol       Date:  1977-04

7.  Measurement of regional bone and bone marrow blood flow in the rabbit using the hydrogen washout technique.

Authors:  L A Whiteside; P A Lesker; D J Simmons
Journal:  Clin Orthop Relat Res       Date:  1977 Jan-Feb       Impact factor: 4.176

8.  A new instrument for continuous measurement of tissue blood flow by light beating spectroscopy.

Authors:  G E Nilsson; T Tenland; P A Obert
Journal:  IEEE Trans Biomed Eng       Date:  1980-01       Impact factor: 4.538

9.  Studies of skeletal tracer kinetics. III. Tc-99m(Sn)methylenediphosphonate uptake in the canine tibia as a function of blood flow.

Authors:  V V Sagar; J M Piccone; N D Charkes
Journal:  J Nucl Med       Date:  1979-12       Impact factor: 10.057

10.  Laser Doppler flowmetry for bone blood flow measurement: correlation with microsphere estimates and evaluation of the effect of intracapsular pressure on femoral head blood flow.

Authors:  M F Swiontkowski; S Tepic; S M Perren; R Moor; R Ganz; B A Rahn
Journal:  J Orthop Res       Date:  1986       Impact factor: 3.494

View more
  6 in total

1.  An in-vitro analysis of two laser Doppler flowmetry systems for evaluation of bone perfusion.

Authors:  G K Carpenter; M F Swiontkowski
Journal:  Calcif Tissue Int       Date:  1991-06       Impact factor: 4.333

2.  Role of the extraosseus blood supply in osteoarthritic femoral heads?

Authors:  Ralf Schoeniger; Norman Espinosa; Rafael J Sierra; Michael Leunig; Reinhold Ganz
Journal:  Clin Orthop Relat Res       Date:  2009-04-21       Impact factor: 4.176

3.  Changes to patellar blood flow after minimally invasive total knee arthroplasty.

Authors:  Masahiro Hasegawa; Goshin Kawamura; Hiroki Wakabayashi; Akihiro Sudo; Atsumasa Uchida
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-06-18       Impact factor: 4.342

4.  Evaluation of a laser Doppler flowmetry implantable fiber system for determination of threshold thickness for flow detection in bone.

Authors:  E H Schemitsch; M J Kowalski; M F Swiontkowski
Journal:  Calcif Tissue Int       Date:  1994-09       Impact factor: 4.333

5.  Assessment of the relationship between standard probe and implantable fiber measurements of cortical bone blood flow: a canine study.

Authors:  R Jain; N Podworny; G I Anderson; E H Schemitsch
Journal:  Calcif Tissue Int       Date:  1996-07       Impact factor: 4.333

6.  The effect of blood flow on the material properties of bone.

Authors:  F McDonald; T R Pitt Ford
Journal:  Ann Biomed Eng       Date:  1994 Mar-Apr       Impact factor: 3.934

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.