Literature DB >> 6190402

Long-term results of valve implants in filtering surgery for eyes with neovascular glaucoma.

T Krupin, P Kaufman, A I Mandell, S A Terry, R Ritch, S M Podos, B Becker.   

Abstract

Filtration surgery was performed with a pressure-sensitive, unidirectional valve implant in 79 eyes with neovascular glaucoma. The device consisted of an open Supramid tube (outside diameter 0.58 mm) sealed to a Silastic tube with a slit valve. The Supramid tube was inserted at the corneoscleral limbus 1 to 4 mm into the anterior chamber. The Silastic portion was located under a scleral flap. Of the 79 eyes, 53 had postoperative intraocular pressures less than or equal to 24 mm Hg after a mean follow-up period of 23.7 +/- 10.9 months. Bleb revision for external scarring was required in ten of these 53 eyes and postoperative medical therapy was required in 26. The valve implant failed to control intraocular pressure in 26 of the 79 eyes. Failure was secondary to scarring of the external bleb in 18 eyes and to closure of the internal Supramid tube in five eyes. Mortality during the follow-up period was high: 12 of the 53 successfully treated patients and five of the unsuccessfully treated patients died.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6190402     DOI: 10.1016/0002-9394(83)90064-8

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  17 in total

1.  Baerveldt implant in refractory glaucoma: long-term results and factors influencing outcome.

Authors:  S Roy; E Ravinet; A Mermoud
Journal:  Int Ophthalmol       Date:  2001       Impact factor: 2.031

2.  A one-piece ocular drainage implant for glaucoma surgery: a preliminary report.

Authors:  M Kivalo; C Raitta; T Mononen
Journal:  Acta Vet Scand       Date:  1992       Impact factor: 1.695

3.  Clinicopathological findings 11 months after implantation of a functioning aqueous-drainage silicone implant.

Authors:  W Philipp; G Klima; K Miller
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1990       Impact factor: 3.117

4.  [New concepts for pressure-controlled glaucoma implants].

Authors:  R Allemann; O Stachs; K Falke; W Schmidt; S Siewert; K Sternberg; B Chichkov; A Wree; K-P Schmitz; R F Guthoff
Journal:  Ophthalmologe       Date:  2013-08       Impact factor: 1.059

5.  Clinical experience of e-PTFE membrane implant surgery for refractory glaucoma.

Authors:  C Kim; Y Kim; S Choi; S Lee; B Ahn
Journal:  Br J Ophthalmol       Date:  2003-01       Impact factor: 4.638

6.  Tissue response to aqueous drainage in a functioning Molteno implant.

Authors:  K U Loeffler; J L Jay
Journal:  Br J Ophthalmol       Date:  1988-01       Impact factor: 4.638

7.  Panretinal cryotherapy in neovascular disease.

Authors:  S A Vernon; H Cheng
Journal:  Br J Ophthalmol       Date:  1988-06       Impact factor: 4.638

8.  Efficacy and safety of the Ahmed glaucoma valve implant in Chinese eyes with complicated glaucoma.

Authors:  J S Lai; A S Poon; J K Chua; C C Tham; A T Leung; D S Lam
Journal:  Br J Ophthalmol       Date:  2000-07       Impact factor: 4.638

9.  Investigations of the reasons for success and failure in the anterior shunt-to-the-encircling-band procedure in the treatment of refractory glaucoma.

Authors:  S S Schocket
Journal:  Trans Am Ophthalmol Soc       Date:  1986

10.  Managing high risk glaucoma with the Ahmed valve implant: 20 years of experience.

Authors:  Tryfon Rotsos; Anastasia Tsioga; Konstantinos Andreanos; Andreas Diagourtas; Petros Petrou; Ilias Georgalas; Dimitrios Papaconstantinou
Journal:  Int J Ophthalmol       Date:  2018-02-18       Impact factor: 1.779

View more