Plasma glucose measurement with the Yellow Springs Glucose Analyzer.

K S Chua, I K Tan.   

Abstract

The Yellow Springs Glucose Analyzer, a device for the quantitative measurement of glucose concentrations, involves the use of immobilized glucose oxidase, incorporated on a membrane covering a hydrogen peroxide sensor. Operation of the instrument is simple. After an initial calibration, 25 microliter of plasma is injected into a reaction chamber. At 45 s a digital result for glucose is displayed. The within-batch coefficient of variation for the method is 1.2% or less for glucose concentrations of 0.94 to 3.98 g/liter. The between-batch coefficient of variation is 5.8% or less for glucose concentrations of 0.29 to 2.91 g/liter. Concentration and readout are linearly related to at least 4.6 g/liter. Analytical recoveries ranged from 100 to 102%. Carry-over was negligible. Values for glucose concentration obtained with the instrument compared well (r = 0.997) with those obtained with the Beckman Glucose Analyzer.

Entities:  

Mesh:

Substances:

Year:  1978        PMID: 618647

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  6 in total

1.  Insulin pump basal adjustment for exercise in type 1 diabetes: a randomised crossover study.

Authors:  Sybil A McAuley; Jodie C Horsburgh; Glenn M Ward; André La Gerche; Judith L Gooley; Alicia J Jenkins; Richard J MacIsaac; David N O'Neal
Journal:  Diabetologia       Date:  2016-05-11       Impact factor: 10.122

2.  Open flow microperfusion: approach to in vivo glucose monitoring.

Authors:  G P Rigby; P Crump; P Vadgama
Journal:  Med Biol Eng Comput       Date:  1995-03       Impact factor: 2.602

Review 3.  Optimisation of enzyme electrodes.

Authors:  L X Tang; P Vadgama
Journal:  Med Biol Eng Comput       Date:  1990-05       Impact factor: 2.602

4.  Measurement of glucose in blood with a phenylboronic acid optical sensor.

Authors:  Graham J Worsley; Guilhem A Tourniaire; Kathryn E S Medlock; Felicity K Sartain; Hazel E Harmer; Michael Thatcher; Adrian M Horgan; John Pritchard
Journal:  J Diabetes Sci Technol       Date:  2008-03

5.  Plasma glucose measurement with the Yellow Springs Glucose 2300 STAT and the Olympus AU640.

Authors:  P J Twomey
Journal:  J Clin Pathol       Date:  2004-07       Impact factor: 3.411

6.  Different glucose analyzers report different glucose concentration values in term newborns.

Authors:  Rina P Duke; Shasha Bai; Joshua A Bornhorst; Nahed O ElHassan; Jeffrey R Kaiser
Journal:  Front Pediatr       Date:  2022-09-21       Impact factor: 3.569

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.