Literature DB >> 6149404

How far is the cardiac output?

N E Haites, F M McLennan, D H Mowat, J M Rawles.   

Abstract

Measurement of volumetric cardiac output is technically difficult and poorly reproducible, and the technique is unsuitable for use in the majority of patients in whom a knowledge of overall cardiovascular function would be desirable. Interpretation of a single measurement in a patient is difficult because little is known about volumetric cardiac output in normal subjects and the available techniques of measurement are very complex or invasive. Linear cardiac output, in contrast, can be simply, non-invasively, and reproducibly measured at the bedside by doppler ultrasound. The systolic-velocity integral of a single heart beat (stroke distance) multiplied by the heart rate gives minute distance; this may be envisaged as the distance travelled by mid-stream blood in the aorta in a minute. Providing there is no aortic disease, minute distance may be used as an absolute indication of cardiac output and for following serial changes.

Entities:  

Mesh:

Year:  1984        PMID: 6149404     DOI: 10.1016/s0140-6736(84)91118-8

Source DB:  PubMed          Journal:  Lancet        ISSN: 0140-6736            Impact factor:   79.321


  15 in total

1.  Automated non-invasive measurement of cardiac output by the carbon dioxide rebreathing method: comparisons with dye dilution and thermodilution.

Authors:  A E Russell; S A Smith; M J West; P E Aylward; R J McRitchie; R M Hassam; R B Minson; L M Wing; J P Chalmers
Journal:  Br Heart J       Date:  1990-03

2.  Suprasternal Doppler ultrasound for assessment of stroke distance.

Authors:  C Childs; S Goldring; W Tann; V F Hillier
Journal:  Arch Dis Child       Date:  1998-09       Impact factor: 3.791

3.  Partial Volume Effect and Correction for 3-D Color Flow Acquisition of Volumetric Blood Flow.

Authors:  Oliver D Kripfgans; Jonathan M Rubin; Stephen Z Pinter; James Jago; Ron Leichner; J Brian Fowlkes
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-08-09       Impact factor: 2.725

4.  Is the pulse in atrial fibrillation irregularly irregular?

Authors:  J M Rawles; E Rowland
Journal:  Br Heart J       Date:  1986-07

5.  Effect of age and blood pressure on aortic size and stroke distance.

Authors:  B A Towfiq; J Weir; J M Rawles
Journal:  Br Heart J       Date:  1986-06

6.  Doppler-derived cardiac output in healthy newborn infants in relation to physiological patency of the ductus arteriosus.

Authors:  H Hirsimäki; P Kero; O Wanne; R Erkkola; Z Makoi
Journal:  Pediatr Cardiol       Date:  1988       Impact factor: 1.655

7.  Reproducibility of linear cardiac output measurement by Doppler ultrasound alone.

Authors:  F M McLennan; N E Haites; J D Mackenzie; M K Daniel; J M Rawles
Journal:  Br Heart J       Date:  1986-01

8.  Delay between the onset of symptoms of acute myocardial infarction and seeking medical assistance is influenced by left ventricular function at presentation.

Authors:  R J Trent; E L Rose; J N Adams; K P Jennings; J M Rawles
Journal:  Br Heart J       Date:  1995-02

9.  Non-invasive pulmonary blood flow measurement by means of CO2 analysis of expiratory gases.

Authors:  R J Bosman; C P Stoutenbeek; D F Zandstra
Journal:  Intensive Care Med       Date:  1991       Impact factor: 17.440

10.  Reference values of aortic flow velocity integral in 1193 healthy infants, children, and adolescents to quickly estimate cardiac stroke volume.

Authors:  Christiane Pees; Eva Glagau; Jakob Hauser; Ina Michel-Behnke
Journal:  Pediatr Cardiol       Date:  2013-01-24       Impact factor: 1.655

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.