Literature DB >> 5762647

Everest MS: Measurement of digoxin in plasma and its use in diagnosis of digoxin intoxication.

D G Grahame-Smith.   

Abstract

A method for measuring the plasma-digoxin concentration uses the measurement of its inhibitory effect on (86)Rb uptake by human red cells in vitro. Patients receiving digoxin in whom there was no clinical evidence of digoxin intoxication had plasma digoxin concentrations ranging from 0.8 to 4.5 mmug./ml. Patients presenting with convincing clinical evidence of digoxin intoxication had plasma digoxin concentrations ranging from 4 to greater than 8 mmug./ml. It is suggested that the plasma digoxin concentration may be used as an aid in the diagnosis of digoxin intoxication.

Entities:  

Mesh:

Substances:

Year:  1969        PMID: 5762647      PMCID: PMC1982164          DOI: 10.1136/bmj.1.5639.286

Source DB:  PubMed          Journal:  Br Med J        ISSN: 0007-1447


  6 in total

1.  A METHOD FOR MEASURING PLASMA LEVELS OF DIGITALIS GLYCOSIDES.

Authors:  J M LOWENSTEIN
Journal:  Circulation       Date:  1965-02       Impact factor: 29.690

2.  The action of cardiac glycosides on sodium and potassium movements in human red cells.

Authors:  I M GLYNN
Journal:  J Physiol       Date:  1957-04-03       Impact factor: 5.182

3.  A comparison of potassium 42, rubidium 86, and cesium 134 as tracers of potassium in the study of cation metabolism of human erythrocytes in vitro.

Authors:  W D LOVE; G E BURCH
Journal:  J Lab Clin Med       Date:  1953-03

4.  Double isotope dilution derivative assay of digitoxin in plasma, urine, and stool of patients maintained on the drug.

Authors:  D A Lukas; R E Peterson
Journal:  J Clin Invest       Date:  1966-05       Impact factor: 14.808

5.  Reappraisal of digitalis. V. Evaluation of criteria for determining effect of digitalis in man.

Authors:  A F Lyon; A C DeGraff
Journal:  Am Heart J       Date:  1967-01       Impact factor: 4.749

6.  The measurement of digitoxin in human serum by radioimmunoassay.

Authors:  G C Oliver; B M Parker; D L Brasfield; C W Parker
Journal:  J Clin Invest       Date:  1968-05       Impact factor: 14.808

  6 in total
  22 in total

1.  Stimulation and inhibition of the sodium pump by cardioactive steroids in relation to their binding sites and their inotropic effect on guinea-pig isolated atria.

Authors:  J Ghysel-Burton; T Godfraind
Journal:  Br J Pharmacol       Date:  1979-06       Impact factor: 8.739

Review 2.  Variability in response to drugs.

Authors:  M D Rawlins
Journal:  Br Med J       Date:  1974-10-12

3.  Zero plasma digoxin levels in patients on oral digoxin therapy.

Authors:  P F Binnion
Journal:  Ir J Med Sci       Date:  1974-11       Impact factor: 1.568

Review 4.  [Determination of digoxin and digitoxin in the blood and their clinical significance].

Authors:  G Bodem; H J Gilfrich
Journal:  Klin Wochenschr       Date:  1973-01-15

5.  Human plasma digoxin levels.

Authors:  P F Binnion
Journal:  Ir J Med Sci       Date:  1974-01       Impact factor: 1.568

6.  Effect of prolonged ouabain treatment of Na, K, Cl and Ca concentration and fluxes in cultured human cells.

Authors:  J F Lamb; D McCall
Journal:  J Physiol       Date:  1972-09       Impact factor: 5.182

7.  Plasma digoxin concentration--its relation to digoxin dosage and clinical effects in patients with atrial fibrillation.

Authors:  A Redfors
Journal:  Br Heart J       Date:  1972-04

8.  Long-term digoxin treatment in general practice.

Authors:  P Curtis
Journal:  Br Med J       Date:  1975-12-27

9.  One hundred digitalis blood levels. A utilization review.

Authors:  W B Hladik; C A Dujovne
Journal:  Eur J Clin Pharmacol       Date:  1979-07       Impact factor: 2.953

10.  Ouabain-specific antibodies: immunochemical properties and reversal of Na + , K + -activated adenosine triphosphatase inhibition.

Authors:  T W Smith
Journal:  J Clin Invest       Date:  1972-06       Impact factor: 14.808

View more