Literature DB >> 5717551

Residual formaldehyde after low-temperature steam and formaldehyde sterilization.

G L Gibson, H P Johnston, V E Turkington.   

Abstract

The levels of formaldehyde remaining in various articles have been estimated immediately after a low-temperature steam and formaldehyde sterilizing process and after various periods of aeration. These levels have been compared with the levels of ethylene oxide remaining after exposure to an ethylene oxide sterilizing process. In rubber and polythene and a plastic, formaldehyde levels are low and slowly fall even further. Ethylene oxide levels are relatively much higher even after seven days' aeration. It is not considered that the residual levels of formaldehyde in rubber, polythene, and a plastic should constitute a danger. Residual levels of formaldehyde in fabrics and paper are higher but this may be of value by giving a self-disinfecting action on storage.

Entities:  

Mesh:

Substances:

Year:  1968        PMID: 5717551      PMCID: PMC473959          DOI: 10.1136/jcp.21.6.771

Source DB:  PubMed          Journal:  J Clin Pathol        ISSN: 0021-9746            Impact factor:   3.411


  6 in total

1.  FORMALDEHYDE AS A CONTACT ALLERGEN IN TESTILES. FORMALDEHYDE CLOTHING DERMATITIS. A TEN YEAR PERIOD IN-PATIENT SERIES (1953-1962).

Authors:  K WEREIDE
Journal:  Acta Allergol       Date:  1964

2.  STERILIZING PROCEDURES FOR HEART-LUNG MACHINES.

Authors:  J C KELSEY
Journal:  J Clin Pathol       Date:  1963-11       Impact factor: 3.411

3.  Contact dermatitis due to formaldehyde in textiles 1934-1958. Preliminary report.

Authors:  P V MARCUSSEN
Journal:  Acta Derm Venereol       Date:  1959       Impact factor: 4.437

4.  Control of an outbreak of staphylococcal infection in a hospital.

Authors:  W A GILLESPIE; V G ALDER
Journal:  Lancet       Date:  1957-03-23       Impact factor: 79.321

5.  Use of formaldehyde for the disinfection of hospital woollen blankets in laundering.

Authors:  J C Dickinson; R E Wagg
Journal:  J Appl Bacteriol       Date:  1967-08

6.  Formaldehyde contact dermatitis. I. A simple method for determination of small amounts of formaldehyde.

Authors:  S G BLOHM
Journal:  Acta Derm Venereol       Date:  1959       Impact factor: 4.437

  6 in total
  4 in total

1.  [Sterilization and disinfection in risk zones (author's transl)].

Authors:  B Schmidt
Journal:  Langenbecks Arch Chir       Date:  1974

2.  Testing a steam-formaldehyde sterilizer for gas penetration efficiency.

Authors:  S J Line; J K Pickerill
Journal:  J Clin Pathol       Date:  1973-09       Impact factor: 3.411

3.  Processing urinary endoscopes in a low-temperature steam and formaldehyde autoclave.

Authors:  G L Gibson
Journal:  J Clin Pathol       Date:  1977-03       Impact factor: 3.411

4.  Disinfection of cystoscopes by subatmospheric steam and steam and formaldehyde at 80 degrees C.

Authors:  V G Alder; J C Gingell; J P Mitchell
Journal:  Br Med J       Date:  1971-09-18
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.