Literature DB >> 4752414

Testing a steam-formaldehyde sterilizer for gas penetration efficiency.

S J Line, J K Pickerill.   

Abstract

A test piece is described for monitoring the performance of low-temperature steam-with-formaldehyde sterilizers. Comparative tests have shown it to be more difficult to penetrate than an arterial catheter when exposed to the same sterilizing conditions. It is permanent and simple to use and maintain. The growth or non-growth of bacterial spores, in the convenient form of spore strips, is used to indicate the efficacy of sterilization.

Entities:  

Mesh:

Substances:

Year:  1973        PMID: 4752414      PMCID: PMC477858          DOI: 10.1136/jcp.26.9.716

Source DB:  PubMed          Journal:  J Clin Pathol        ISSN: 0021-9746            Impact factor:   3.411


  5 in total

1.  The Bowie and Dick autoclave tape test.

Authors:  J H BOWIE; J C KELSEY; G R THOMPSON
Journal:  Lancet       Date:  1963-03-16       Impact factor: 79.321

2.  Use of gaseous antimicrobial agents with special reference to ethylene oxide.

Authors:  J C Kelsey
Journal:  J Appl Bacteriol       Date:  1967-04

3.  Disinfection of cystoscopes by subatmospheric steam and steam and formaldehyde at 80 degrees C.

Authors:  V G Alder; J C Gingell; J P Mitchell
Journal:  Br Med J       Date:  1971-09-18

4.  Disinfection of heat-sensitive material by low-temperature steam and formaldehyde.

Authors:  V G Alder; A M Brown; W A Gillespie
Journal:  J Clin Pathol       Date:  1966-01       Impact factor: 3.411

5.  Residual formaldehyde after low-temperature steam and formaldehyde sterilization.

Authors:  G L Gibson; H P Johnston; V E Turkington
Journal:  J Clin Pathol       Date:  1968-11       Impact factor: 3.411

  5 in total
  4 in total

1.  The use of ethylene oxide and low temperature steam/formaldehyde in hospitals.

Authors:  G A Ayliffe
Journal:  Infection       Date:  1989 Mar-Apr       Impact factor: 3.553

2.  Quantitative recovery of spores from thermophilic spore papers.

Authors:  P H Everall; C A Morris
Journal:  J Clin Pathol       Date:  1978-05       Impact factor: 3.411

3.  Processing urinary endoscopes in a low-temperature steam and formaldehyde autoclave.

Authors:  G L Gibson
Journal:  J Clin Pathol       Date:  1977-03       Impact factor: 3.411

4.  Ethylene oxide sterilisation--is it safe?

Authors:  E H Gillespie; J M Jackson; G R Owen
Journal:  J Clin Pathol       Date:  1979-11       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.