Literature DB >> 479215

Characteristics of tissue growth into Proplast and porous polyethylene implants in bone.

M Spector, S L Harmon, A Kreutner.   

Abstract

(1) Bone does not form within internal pores of undistorted Proplast implants because of the small interconnecting pore size of the material; (2) the nonosseous, fibrous tissue which exists in the pores of Proplast implants in bone is not attached to the surrounding bone (i.e., Sharpey's fibers are not present). The load-bearing support which can be afforded by Proplast implants is limited by the incomplete bone ingrowth along the margins of the material and the tensile strength of Proplast.

Entities:  

Mesh:

Substances:

Year:  1979        PMID: 479215     DOI: 10.1002/jbm.820130502

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  11 in total

1.  Clinical experience with the Medpor porous polyethylene implant.

Authors:  T Wellisz
Journal:  Aesthetic Plast Surg       Date:  1993       Impact factor: 2.326

Review 2.  Regulation of hematopoiesis.

Authors:  J F Desforges
Journal:  West J Med       Date:  1984-07

3.  Cementless Gustilo-Kyle and BIAS total hip arthroplasty: 2- to 5-year results.

Authors:  H Kienapfel; J Martell; A Rosenberg; J Galante
Journal:  Arch Orthop Trauma Surg       Date:  1991       Impact factor: 3.067

4.  Porous polyethylene and proplast: their behavior in a bony implant bed.

Authors:  A Berghaus; G Mulch; M Handrock
Journal:  Arch Otorhinolaryngol       Date:  1984

5.  Enhancing facial esthetics by other modalities.

Authors:  Thotapalli Suman
Journal:  Int J Dent       Date:  2011-08-14

Review 6.  Ahmed glaucoma valve implant: surgical technique and complications.

Authors:  Ivano Riva; Gloria Roberti; Francesco Oddone; Anastasios Gp Konstas; Luciano Quaranta
Journal:  Clin Ophthalmol       Date:  2017-02-17

7.  In vivo tissue response and durability of five novel synthetic polymers in a rabbit model.

Authors:  E Sahin; C Cingi; G Eskiizmir; N Altintoprak; A Calli; C Calli; I Yilgör; E Yilgör
Journal:  Acta Otorhinolaryngol Ital       Date:  2016-04-29       Impact factor: 2.124

8.  Maxillofacial reconstruction with Medpor porous polyethylene implant: a case series study.

Authors:  Mansour Khorasani; Pejman Janbaz; Farshid Rayati
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2018-06-26

9.  Use of an anionic collagen matrix made from bovine intestinal serosa for in vivo repair of cranial defects.

Authors:  Mariane Silva Pettian; Ana Maria de Guzzi Plepis; Virginia da Conceição Amaro Martins; Geovane Ribeiro Dos Santos; Clovis Antônio Lopes Pinto; Ewerton Alexandre Galdeano; Amanda Regina Alves Calegari; Carlos Alberto de Moraes; Marcelo Rodrigues da Cunha
Journal:  PLoS One       Date:  2018-07-12       Impact factor: 3.240

10.  Clinical Experience with the M4 Ahmed Glaucoma Drainage Implant.

Authors:  Ilya Sluch; Brett Gudgel; Justin Dvorak; Mary Anne Ahluwalia; Kai Ding; Steve Vold; Steven Sarkisian
Journal:  J Curr Glaucoma Pract       Date:  2017-10-27
View more