Literature DB >> 472012

Stripping of X-ray bremsstrahlung spectra up to 300 kVp on a desk type computer.

W W Seelentag, W Panzer.   

Abstract

The direct result of a spectrometric measurement is a pulse height distribution. In the energy region up to 300 keV three corrections in particular need to be applied to get the photon spectrum: corrections for K-escape, Compton scattering and inefficient photon absorption. A simple 'stripping' procedure is described which may be implemented on a desk type computer. All data necessary are either available in the literature or may be derived from the measurement of very heavily filtered X-ray spectra. The accuracy of the procedure is better than +/- 5% of the peak value. Results are compared with a more detailed stripping procedure, based on Monte Carlo calculated data.

Entities:  

Mesh:

Year:  1979        PMID: 472012     DOI: 10.1088/0031-9155/24/4/008

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  Experimental and Monte Carlo-simulated spectra of standard mammography-quality beams.

Authors:  M G David; E J Pires; M A Bernal; J G Peixoto; C E Dealmeida
Journal:  Br J Radiol       Date:  2011-10-18       Impact factor: 3.039

2.  Use of a laser-guided collimation system to perform direct kilovoltage x-ray spectra measurements on a linear accelerator onboard imager.

Authors:  Zachary Grelewicz; Andrew H Belcher; Rodney D Wiersma
Journal:  Med Phys       Date:  2018-10-09       Impact factor: 4.071

3.  Image quality control for digital mammographic systems: initial experience and outlook.

Authors:  H Roehrig; T Yu; E Krupinski
Journal:  J Digit Imaging       Date:  1995-05       Impact factor: 4.056

4.  Experimental verification of reverse order of diagnostic X-ray beam quality in voltage-ripple dependence.

Authors:  M Matsumoto; H Kubota; Y Ozaki; H Kanamori
Journal:  Med Biol Eng Comput       Date:  1995-01       Impact factor: 2.602

5.  Experimental separation of diagnostic X-ray spectra into scatter and primary components.

Authors:  H Kubota; Y Ozaki; M Matsumoto; H Kanamori
Journal:  Med Biol Eng Comput       Date:  1994-07       Impact factor: 2.602

6.  Establishment of ANSI N13.11 X-ray radiation fields for personal dosimetry performance test by computation and experiment.

Authors:  J L Kim; B H Kim; S Y Chang; J K Lee
Journal:  Environ Health Perspect       Date:  1997-12       Impact factor: 9.031

7.  Acquisition of Quasi-Monochromatic Dual-Energy in a Microfocus X-ray Generator and Development of Applied Technology.

Authors:  Hiroaki Hasegawa; Masanori Sato
Journal:  Diagnostics (Basel)       Date:  2019-03-04
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.