Literature DB >> 4601521

Intraaortic balloon counterpulsation. A review of physiological principles, clinical results, and device safety.

K T Weber, J S Janicki.   

Abstract

Mesh:

Year:  1974        PMID: 4601521     DOI: 10.1016/s0003-4975(10)65706-2

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


× No keyword cloud information.
  27 in total

1.  Twenty-four hour left ventricular bypass with a centrifugal blood pump.

Authors:  E F Berstein; G A DeLaria; K H Johansen; R L Shuman; P Stasz; S Reich
Journal:  Ann Surg       Date:  1975-04       Impact factor: 12.969

2.  Rapid complete reversal of systemic hypoperfusion after intra-aortic balloon pump counterpulsation and survival in cardiogenic shock complicating an acute myocardial infarction.

Authors:  Krishnan Ramanathan; Michael E Farkouh; John E Cosmi; John K French; Shannon M Harkness; Vladimír Džavík; Lynn A Sleeper; Judith S Hochman
Journal:  Am Heart J       Date:  2011-08       Impact factor: 4.749

3.  Intra-aortic balloon pump prevents transtracheal Doppler endotracheal tube measurements of cardiac output.

Authors:  J M Gayes
Journal:  J Clin Monit       Date:  1991-10

4.  A novel counterpulsation mode of rotary left ventricular assist devices can enhance myocardial perfusion.

Authors:  Masahiko Ando; Yoshiaki Takewa; Takashi Nishimura; Kenji Yamazaki; Shunei Kyo; Minoru Ono; Tomonori Tsukiya; Toshihide Mizuno; Yoshiyuki Taenaka; Eisuke Tatsumi
Journal:  J Artif Organs       Date:  2011-05-28       Impact factor: 1.731

5.  A novel counterpulse drive mode of continuous-flow left ventricular assist devices can minimize intracircuit backward flow during pump weaning.

Authors:  Masahiko Ando; Takashi Nishimura; Yoshiaki Takewa; Daisuke Ogawa; Kenji Yamazaki; Koichi Kashiwa; Shunei Kyo; Minoru Ono; Yoshiyuki Taenaka; Eisuke Tatsumi
Journal:  J Artif Organs       Date:  2011-01-18       Impact factor: 1.731

6.  Left ventricular afterload and systemic hydraulic power during in-series cardiac assistance: studies using intraaortic balloon pumping in dogs.

Authors:  D Jaron
Journal:  Ann Biomed Eng       Date:  1977-06       Impact factor: 3.934

7.  Extended use of intra-aortic balloon pumping in peripartum cardiomyopathy.

Authors:  C O Brantigan; J B Grow; F W Schoonmaker
Journal:  Ann Surg       Date:  1976-01       Impact factor: 12.969

Review 8.  Closed-loop physiological control of the heart.

Authors:  K Sagawa
Journal:  Ann Biomed Eng       Date:  1980       Impact factor: 3.934

9.  The Use of Intra-aortic Balloon Pump in a Real-World Setting: A Comparison between Survivors and Nonsurvivors from Acute Coronary Syndrome Treated with IABP. The Jakarta Acute Coronary Syndrome Registry.

Authors:  Surya Dharma; Iwan Dakota; Isman Firdaus; Alexander J Wardeh; J Wouter Jukema
Journal:  Int J Angiol       Date:  2013-12

10.  Effects of intra-aortic balloon counterpulsation in a model of septic shock.

Authors:  Steven B Solomon; Peter C Minneci; Katherine J Deans; Jing Feng; Peter Q Eichacker; Steven M Banks; Robert L Danner; Charles Natanson; Michael A Solomon
Journal:  Crit Care Med       Date:  2009-01       Impact factor: 7.598

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.