Literature DB >> 4072566

Performance evaluation of reflectance meter for glucose determination by two different reagent strips.

D Spotti, C Rocco, O Carandente.   

Abstract

Serum glucose concentrations of 112 blood samples determined by the GOD/POD/Trinder method were compared with values obtained on whole blood by means of the Glucometer reflectance meter and two different reagent strips, Dextrostix and an experimental strip (GX 947822), in order to establish over a wide range of glucose concentrations, the precision and reproducibility of reflectometric methods. The two methods examined showed an excellent correlation with the reference method, particularly if data were corrected for the individual hematocrit value, and both accuracy and precision were reasonably satisfactory.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 4072566     DOI: 10.1007/BF02590789

Source DB:  PubMed          Journal:  Acta Diabetol Lat        ISSN: 0001-5563


  7 in total

1.  Evaluation of a reagent-strip method for glucose in whole blood, as compared with a hexokinase method.

Authors:  T C Stewart
Journal:  Clin Chem       Date:  1976-01       Impact factor: 8.327

2.  Evaluation of an improved Reagent Strip system for measuring blood glucose.

Authors:  A E Davis
Journal:  Am J Med Technol       Date:  1976-01

3.  Incorrect least-squares regression coefficients in method-comparison analysis.

Authors:  P J Cornbleet; N Gochman
Journal:  Clin Chem       Date:  1979-03       Impact factor: 8.327

4.  Evaluation of two methods of self blood glucose monitoring by trained insulin-dependent diabetic adolescents outside the hospital.

Authors:  A Schiffrin; M Desrosiers; M Belmonte
Journal:  Diabetes Care       Date:  1983 Mar-Apr       Impact factor: 19.112

5.  Comparison of various methods for rapid glucose estimation.

Authors:  R S Clements; N A Keane; K A Kirk; B R Boshell
Journal:  Diabetes Care       Date:  1981 May-Jun       Impact factor: 19.112

6.  A comparison of accuracy and estimated cost of methods for home blood glucose monitoring.

Authors:  B Shapiro; P J Savage; D Lomatch; T Gniadek; R Forbes; R Mitchell; K Hein; R Starr; M Nutter; B Scherdt
Journal:  Diabetes Care       Date:  1981 May-Jun       Impact factor: 19.112

7.  A comparison study of blood glucose test strips.

Authors:  R C Worth; K Harrison; J Anderson; D G Johnston; K G Alberti
Journal:  Diabetes Care       Date:  1981 May-Jun       Impact factor: 19.112

  7 in total