Literature DB >> 4071459

Evaluation of Biox IIA ear oximeter.

P M Tweeddale, N J Douglas.   

Abstract

Arterial blood gas tensions, pH, and carboxyhaemoglobin were measured on 322 occasions in 165 patients and the actual oxygen saturation of the haemoglobin (Sao2) was compared with the ear oxygen saturation (SEO2) recorded during the arterial sampling with a Biox IIA ear oximeter. The overall agreement between SEO2 and Sao2 was good, with a mean difference in saturation (SEO2-Sao2) of + 1.5% (SD 3.0). The difference in saturation remained similar at all levels of arterial saturation observed and was unaffected by carboxyhaemoglobin concentration. On four occasions (1% of readings), however, SEO2 and Sao2 differed by more than 10% and such occasional errors might be misleading in clinical practice.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 4071459      PMCID: PMC1020558          DOI: 10.1136/thx.40.11.825

Source DB:  PubMed          Journal:  Thorax        ISSN: 0040-6376            Impact factor:   9.139


  4 in total

1.  Oxygen affinity of human blood in presence of carbon monoxide.

Authors:  C R Collier
Journal:  J Appl Physiol       Date:  1976-03       Impact factor: 3.531

2.  Accuracy sensitivity to carboxyhemoglobin, and speed of response of the Hewlett-Packard 47201A ear oximeter.

Authors:  N J Douglas; H M Brash; P K Wraith; P M Calverley; R J Leggett; L McElderry; D C Flenley
Journal:  Am Rev Respir Dis       Date:  1979-02

3.  Arterial oxygen desaturation following salbutamol inhalation in acute asthma.

Authors:  A Tal; H Pasterkamp; F Leahy
Journal:  Chest       Date:  1984-12       Impact factor: 9.410

4.  The accuracy and response characteristics of a simplified ear oximeter.

Authors:  K R Chapman; A D'Urzo; A S Rebuck
Journal:  Chest       Date:  1983-06       Impact factor: 9.410

  4 in total
  5 in total

1.  The role of pulse oximetry in the accident and emergency department.

Authors:  M A Lambert; J Crinnion
Journal:  Arch Emerg Med       Date:  1989-09

2.  Screening for sleep apnea.

Authors:  J J Nestor; W Likosky; G Sinclair
Journal:  West J Med       Date:  1989-06

3.  Evaluation of the Ohmeda 3700 pulse oximeter.

Authors:  A R Warley; J H Mitchell; J R Stradling
Journal:  Thorax       Date:  1987-11       Impact factor: 9.139

4.  Oxygen desaturation during sleep and exercise in patients with interstitial lung disease.

Authors:  B Midgren; L Hansson; L Eriksson; P Airikkala; D Elmqvist
Journal:  Thorax       Date:  1987-05       Impact factor: 9.139

5.  Non-arterial assessment of blood gas status in patients with chronic pulmonary disease.

Authors:  J S Elborn; M B Finch; C F Stanford
Journal:  Ulster Med J       Date:  1991-10
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.