Literature DB >> 434601

Accuracy sensitivity to carboxyhemoglobin, and speed of response of the Hewlett-Packard 47201A ear oximeter.

N J Douglas, H M Brash, P K Wraith, P M Calverley, R J Leggett, L McElderry, D C Flenley.   

Abstract

We have shown that the Hewlett-Packard 47201A ear oximeter measures arterial O2 saturation within 95 per cent confidence limits of +/- 4 per cent when arterial blood saturation is more than 65 per cent, but at lower saturations the oximeter consistently provides a reading that is too low. The oximeter is sensitive to carboxyhemoglobin, progressively overestimating arterial saturation as carboxyhemoglobin concentration increases from 0 to 18 per cent. The time response is exponential, with a normal time constant of 3 sec, but this is halved in the fast mode or operation.

Entities:  

Mesh:

Substances:

Year:  1979        PMID: 434601     DOI: 10.1164/arrd.1979.119.2.311

Source DB:  PubMed          Journal:  Am Rev Respir Dis        ISSN: 0003-0805


  19 in total

Review 1.  Pulse oximetry: analysis of theory, technology, and practice.

Authors:  M W Wukitsch; M T Petterson; D R Tobler; J A Pologe
Journal:  J Clin Monit       Date:  1988-10

2.  Evaluation of the Datascope ACCUSAT pulse oximeter in healthy adults.

Authors:  Y Mendelson; J C Kent; A Shahnarian; G W Welch; R M Giasi
Journal:  J Clin Monit       Date:  1988-01

3.  Sodium cromoglycate in nocturnal asthma.

Authors:  A D Morgan; J J Connaughton; J R Catterall; C M Shapiro; N J Douglas; D C Flenley
Journal:  Thorax       Date:  1986-01       Impact factor: 9.139

4.  Evaluation of the Ohmeda 3700 pulse oximeter.

Authors:  A R Warley; J H Mitchell; J R Stradling
Journal:  Thorax       Date:  1987-11       Impact factor: 9.139

5.  Effects of protriptyline on sleep related disturbances of breathing in restrictive chest wall disease.

Authors:  A K Simonds; R A Parker; M A Branthwaite
Journal:  Thorax       Date:  1986-08       Impact factor: 9.139

6.  Welcome the new era of oximetry.

Authors:  R J Fallat
Journal:  Intensive Care Med       Date:  1988       Impact factor: 17.440

7.  In vivo response time of transcutaneous oxygen measurement to changes in inspired oxygen in normal adults.

Authors:  J T Brown; M S Schur; B C McClain; E R Kafer
Journal:  Can Anaesth Soc J       Date:  1984-01

8.  Proceedings of the British Thoracic Society. 1985 summer meeting. 3-5 July, York. Abstracts.

Authors: 
Journal:  Thorax       Date:  1985-09       Impact factor: 9.139

9.  Arterial oxygenation during sleep in patients with right-to-left cardiac or intrapulmonary shunts.

Authors:  J R Catterall; N J Douglas; P M Calverley; C M Shapiro; D C Flenley
Journal:  Thorax       Date:  1983-05       Impact factor: 9.139

10.  Carbon monoxide and exercise tolerance in chronic bronchitis and emphysema.

Authors:  P M Calverley; R J Leggett; D C Flenley
Journal:  Br Med J (Clin Res Ed)       Date:  1981-10-03
View more