Literature DB >> 4008195

In vivo assessment of mechanisms controlling corneal hydration.

M R O'Neal, K A Polse.   

Abstract

The endothelial pump and evaporation components of corneal recovery were studied in the in vivo human cornea by inducing corneal swelling with the use of hypoxia and monitoring the subsequent decrease in corneal thickness. Corneal recovery follows a nonlinear time course with the rate of recovery decreasing as the cornea thins. Following 60 micron of induced edema, recovery with the eyes open required an average of 2.5 hr to reach baseline corneal thickness, while recovery with the eyes closed took an average of 4.0 hr to reach the normal physiologic corneal swelling (17 micron). Our analysis indicates that for open eye recovery from 60 micron of swelling, the endothelial pump provides 20%, while the osmotic thinning caused by tear evaporation contributes 80% of recovery. During recovery, the rate of water evaporation from the anterior corneal surface remained relatively steady at 2.5 microliter/cm2 X hr. Comparison of measured vs calculated recovery rates during recovery with the eyes closed suggests that the endothelial pump functions at one speed and that the "pump-leak" theory of corneal hydration control is applicable for the human cornea.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 4008195

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  8 in total

1.  Evaluation of corneal thickness and topography in normal eyes using the Orbscan corneal topography system.

Authors:  Z Liu; A J Huang; S C Pflugfelder
Journal:  Br J Ophthalmol       Date:  1999-07       Impact factor: 4.638

2.  Fluid transport by cultured corneal epithelial cell layers.

Authors:  H Yang; P S Reinach; J P Koniarek; Z Wang; P Iserovich; J Fischbarg
Journal:  Br J Ophthalmol       Date:  2000-02       Impact factor: 4.638

3.  Comparison of Central Corneal Thickness using Anterior Segment Optical Coherence Tomography Versus Ultrasound Pachymetry.

Authors:  Prasanna Venkatesh Ramesh; Kirti Nath Jha; Krishnagopal Srikanth
Journal:  J Clin Diagn Res       Date:  2017-08-01

4.  Clinical estimation of corneal endothelial pump function.

Authors:  W M Bourne
Journal:  Trans Am Ophthalmol Soc       Date:  1998

5.  Oxygen-deficient metabolism and corneal edema.

Authors:  B K Leung; J A Bonanno; C J Radke
Journal:  Prog Retin Eye Res       Date:  2011-07-26       Impact factor: 21.198

6.  Corneal pachymetry mapping with high-speed optical coherence tomography.

Authors:  Yan Li; Raj Shekhar; David Huang
Journal:  Ophthalmology       Date:  2006-05       Impact factor: 12.079

7.  Corneal Swelling with Cosmetic etafilcon A Lenses versus No Lens Wear.

Authors:  Amir M Moezzi; Jalaiah Varikooty; Marc Schulze; William Ngo; Kathrine Osborn Lorenz; Danielle Boree; Lyndon W Jones
Journal:  Optom Vis Sci       Date:  2016-06       Impact factor: 1.973

8.  Corneal Hydration Control in Fuchs' Endothelial Corneal Dystrophy.

Authors:  Katrin Wacker; Jay W McLaren; Katrina M Kane; Keith H Baratz; Sanjay V Patel
Journal:  Invest Ophthalmol Vis Sci       Date:  2016-09-01       Impact factor: 4.799

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.