Literature DB >> 3998116

Clinical comparison of an agar slide blood culture bottle with tryptic soy broth and a conventional blood culture bottle with supplemented peptone broth.

M P Weinstein, L B Reller, S Mirrett, W L Wang, D V Alcid.   

Abstract

The Roche Septi-Chek biphasic blood culture system with tryptic soy broth was compared with a conventional blood culture bottle with supplemented peptone broth in 6,956 paired blood cultures from adult patients. Both systems were inoculated with equal volumes of blood (5 ml) and incubated aerobically (vented) for 2 weeks. More clinically important bacteria and fungi, including Staphylococcus aureus, S. epidermidis, Escherichia coli and other Enterobacteriaceae, Pseudomonas aeruginosa, and Candida albicans and C. tropicalis were recovered from the biphasic system (P less than 0.001). In contrast, more clinically important anaerobic bacteria (P less than 0.001) and Gardnerella vaginalis (P less than 0.05) were recovered in conventional supplemented peptone broth. Staphylococci (P less than 0.01), Enterobacteriaceae other than E. coli (P less than 0.05), and fungi (P less than 0.001) were detected 1 or more days earlier in the biphasic system, whereas streptococci (P less than 0.001) were detected earlier in the conventional bottle. The overall superiority of the agar slide blood culture system compared with conventional blood culture bottles was confirmed by this evaluation. For optimal detection of anaerobic bacteremia, however, the agar slide bottle should be paired with an anaerobic bottle.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3998116      PMCID: PMC271788          DOI: 10.1128/jcm.21.5.815-818.1985

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  9 in total

1.  Controlled evaluation of Trypticase soy broth in agar slide and conventional blood culture systems.

Authors:  M P Weinstein; L B Reller; S Mirrett; W L Wang; D V Alcid
Journal:  J Clin Microbiol       Date:  1985-04       Impact factor: 5.948

2.  Comparison of the Roche Septi-Chek blood culture bottle with a brain heart infusion biphasic medium bottle and with a tryptic soy broth bottle.

Authors:  N K Henry; C M Grewell; C A McLimans; J A Washington
Journal:  J Clin Microbiol       Date:  1984-03       Impact factor: 5.948

3.  Clinical laboratory comparison of a slide blood culture system with a conventional broth system.

Authors:  M A Pfaller; T K Sibley; L M Westfall; J E Hoppe-Bauer; M A Keating; P R Murray
Journal:  J Clin Microbiol       Date:  1982-09       Impact factor: 5.948

4.  Comparison of a slide blood culture system with a supplemented peptone broth culture method.

Authors:  L E Bryan
Journal:  J Clin Microbiol       Date:  1981-10       Impact factor: 5.948

5.  Controlled evaluation of the volume of blood cultured in detection of bacteremia and fungemia.

Authors:  J H Tenney; L B Reller; S Mirrett; W L Wang; M P Weinstein
Journal:  J Clin Microbiol       Date:  1982-04       Impact factor: 5.948

6.  Gardnerella vaginalis bacteremia: a review of thirty cases.

Authors:  L G Reimer; L B Reller
Journal:  Obstet Gynecol       Date:  1984-08       Impact factor: 7.661

7.  The clinical significance of positive blood cultures: a comprehensive analysis of 500 episodes of bacteremia and fungemia in adults. I. Laboratory and epidemiologic observations.

Authors:  M P Weinstein; L B Reller; J R Murphy; K A Lichtenstein
Journal:  Rev Infect Dis       Date:  1983 Jan-Feb

8.  Comparison of acridine orange, methylene blue, and Gram stains for blood cultures.

Authors:  S Mirrett; B A Lauer; G A Miller; L B Reller
Journal:  J Clin Microbiol       Date:  1982-04       Impact factor: 5.948

9.  Controlled evaluation of the effect of atmosphere of incubation on detection of bacteremia and fungemia in supplemented peptone broth.

Authors:  J H Tenney; L B Reller; S Mirrett; M P Weinstein; W L Wang
Journal:  J Clin Microbiol       Date:  1982-09       Impact factor: 5.948

  9 in total
  10 in total

Review 1.  Update on detection of bacteremia and fungemia.

Authors:  L G Reimer; M L Wilson; M P Weinstein
Journal:  Clin Microbiol Rev       Date:  1997-07       Impact factor: 26.132

2.  L. Barth Reller, M.D.

Authors:  Gary V Doern
Journal:  J Clin Microbiol       Date:  2012-02-15       Impact factor: 5.948

3.  Controlled comparison of a new Becton Dickinson agar slant blood culture system with Roche Septi-Chek for the detection of bacteremia and fungemia.

Authors:  L G Reimer; L B Reller; S Mirrett
Journal:  J Clin Microbiol       Date:  1989-12       Impact factor: 5.948

4.  Methods used in the United Kingdom for the culture of micro-organisms from blood.

Authors:  D F Brown; S F Perry
Journal:  J Clin Pathol       Date:  1992-06       Impact factor: 3.411

5.  Risk factors for candidemia in cancer patients: a case-control study.

Authors:  A Karabinis; C Hill; B Leclercq; C Tancrède; D Baume; A Andremont
Journal:  J Clin Microbiol       Date:  1988-03       Impact factor: 5.948

6.  Performance characteristics of a commercially prepared biphasic blood culture bottle.

Authors:  L S Weckbach; J L Staneck
Journal:  J Clin Microbiol       Date:  1986-04       Impact factor: 5.948

7.  Controlled clinical comparison of bioMérieux VITAL and BACTEC NR-660 blood culture systems for detection of bacteremia and fungemia in adults.

Authors:  M L Wilson; S Mirrett; L C McDonald; M P Weinstein; J Fune; L B Reller
Journal:  J Clin Microbiol       Date:  1999-06       Impact factor: 5.948

8.  Controlled evaluation of the agar-slide and radiometric blood culture systems for the detection of bacteremia and fungemia.

Authors:  M P Weinstein; L B Reller; S Mirrett; C W Stratton; L G Reimer; W L Wang
Journal:  J Clin Microbiol       Date:  1986-02       Impact factor: 5.948

9.  Detection of pathogenic Campylobacter species in blood culture systems.

Authors:  W L Wang; M J Blaser
Journal:  J Clin Microbiol       Date:  1986-04       Impact factor: 5.948

10.  Comparison of the lysis-centrifugation and agitated biphasic blood culture systems for detection of fungemia.

Authors:  P R Murray
Journal:  J Clin Microbiol       Date:  1991-01       Impact factor: 5.948

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.