Literature DB >> 3986073

Invasive v. non-invasive measurement of arterial pressure. Comparison of two automatic methods and simultaneously measured direct intra-arterial pressure.

J van Egmond, M Hasenbos, J F Crul.   

Abstract

Two indirect arterial pressure monitors, the Finapres and the Accutorr, were investigated and compared with the direct measurement of intra-arterial pressure. Pressures in patients in a variety of circulatory states were measured and analysed in relation to two types of random error: first, the "intra-individual standard error" (within one session of measurement) and second, the "inter-individual standard error" (between sessions). (This distinction is important, since in routine monitoring of arterial pressure one is usually dealing with the first type of error only.) This study showed that sudden changes in pressure were closely followed by the Finapres. A pressure reading of the Accutorr takes about 15-20 s, meaning that, within this period, variations will not be observed. The accuracy or reproducibility of each method, as expressed in intra-individual variance, diminished in the order Intra-Arterial-Line, Finapres, Accutorr. The inter-individual variation decreased in the order Intra-Arterial-Line, Accutorr, Finapres. Most of the inter-individual variance of the Finapres is probably real because of the more peripheral position of its cuff. A correlation between malfunctioning of the Finapres and vasoconstriction or hypothermia of the finger could not be demonstrated.

Entities:  

Mesh:

Year:  1985        PMID: 3986073     DOI: 10.1093/bja/57.4.434

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  31 in total

1.  Non-invasive studies of peripheral vascular compliance using a non-occluding photoplethysmographic method.

Authors:  E A López-Beltrán; P L Blackshear; S M Finkelstein; J N Cohn
Journal:  Med Biol Eng Comput       Date:  1998-11       Impact factor: 2.602

2.  Evaluation of noninvasive blood pressure recording by photoplethysmography in clinical studies using angiotensin challenges.

Authors:  T Buclin; C Buchwalder-Csajka; H R Brunner; J Biollaz
Journal:  Br J Clin Pharmacol       Date:  1999-10       Impact factor: 4.335

3.  Accuracy of four indirect methods of blood pressure measurement, with hemodynamic correlations.

Authors:  G P Gravlee; J K Brockschmidt
Journal:  J Clin Monit       Date:  1990-10

4.  Assessment of short-term blood pressure variability in anesthetized children: a comparative study between intraarterial and finger blood pressure.

Authors:  I Constant; D Laude; J L Elghozi; I Murat
Journal:  J Clin Monit Comput       Date:  1999-05       Impact factor: 2.502

5.  Haemodynamic effects of changes in atrioventricular and interventricular delay in cardiac resynchronisation therapy show a consistent pattern: analysis of shape, magnitude and relative importance of atrioventricular and interventricular delay.

Authors:  Z I Whinnett; J E R Davies; K Willson; C H Manisty; A W Chow; R A Foale; D Wyn Davies; A D Hughes; J Mayet; D P Francis
Journal:  Heart       Date:  2006-05-18       Impact factor: 5.994

6.  Blood pressure changes associated with tilting in normotensive subjects: differences in response pattern as measured by oscillometry and auscultation.

Authors:  M B Sidery; I A Macdonald
Journal:  Clin Auton Res       Date:  1991-06       Impact factor: 4.435

7.  Continuous finger arterial pressure: utility in the cardiovascular laboratory.

Authors:  B P Imholz; W Wieling; G J Langewouters; G A van Montfrans
Journal:  Clin Auton Res       Date:  1991-03       Impact factor: 4.435

8.  Innovative continuous non-invasive cuffless blood pressure monitoring based on photoplethysmography technology.

Authors:  Juan C Ruiz-Rodríguez; Adolf Ruiz-Sanmartín; Vicent Ribas; Jesús Caballero; Alejandra García-Roche; Jordi Riera; Xavier Nuvials; Miriam de Nadal; Oriol de Sola-Morales; Joaquim Serra; Jordi Rello
Journal:  Intensive Care Med       Date:  2013-06-06       Impact factor: 17.440

9.  The relative accuracies of two automated noninvasive arterial pressure measurement devices.

Authors:  M S Gorback; T J Quill; M L Lavine
Journal:  J Clin Monit       Date:  1991-01

10.  Non-invasive continuous arterial pressure, heart rate and stroke volume measurements during graded head-up tilt in normal man.

Authors:  L A Critchley; F Conway; P J Anderson; B Tomlinson; J A Critchley
Journal:  Clin Auton Res       Date:  1997-04       Impact factor: 4.435

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.