Literature DB >> 3978957

Functional evaluation of total hip arthroplasty with five- to ten-year follow-up evaluation.

T Perrin, L D Dorr, J Perry, J Gronley, D B Hull.   

Abstract

Forty-seven patients with unilateral hip disease had a preoperative and postoperative gait analysis of total hip arthroplasty with a follow-up period of five to ten years. The object was to correlate the levels of function with mechanical loosening. Unilateral total hip arthroplasty in uncomplicated patients restored function to 80% of normal over a two- to four-year period. Patients followed longer than five years appeared to have an accelerated decline in function unassociated with pain. No Class C patient, regardless of age or gait velocity, developed loosening or required revision of the hip prosthesis. Survivorship studies revealed an 85%-90% incidence of loosening by the seventh postoperative year in Class A patients 55 years or younger and those walking preoperatively at more than 50% of normal gait velocity. In these same two groups of patients, the probability of revision for mechanical failure by ten years is 58% for age and 66% for fast walkers. The majority of patients in this study had a technical rating not acceptable by present standards so that these results represent most likely the worst prognosis for longevity of total hip arthroplasty. In high-risk patients, protected ambulation with crutches for six months postoperation may improve their prognosis.

Entities:  

Mesh:

Year:  1985        PMID: 3978957

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  4 in total

1.  No strength or gait benefit of two-incision THA: a brief followup at 1 year.

Authors:  Aaron J Krych; Mark W Pagnano; Krista Coleman Wood; R Michael Meneghini; Kenton Kaufman
Journal:  Clin Orthop Relat Res       Date:  2010-11-13       Impact factor: 4.176

2.  Long-term results and survivorship of the McKee-Farrar total hip prosthesis.

Authors:  T Visuri
Journal:  Arch Orthop Trauma Surg       Date:  1987

3.  Prediction of Polyethylene Wear Rates from Gait Biomechanics and Implant Positioning in Total Hip Replacement.

Authors:  Marzieh M Ardestani; Pedro P Amenábar Edwards; Markus A Wimmer
Journal:  Clin Orthop Relat Res       Date:  2017-03-02       Impact factor: 4.176

4.  Effects of home-based interval walking training on thigh muscle strength and aerobic capacity in female total hip arthroplasty patients: a randomized, controlled pilot study.

Authors:  Yutaka Morishima; Takashi Mizushima; Katsuya Yamauchi; Mayuko Morikawa; Shizue Masuki; Hiroshi Nose
Journal:  PLoS One       Date:  2014-09-30       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.