Errors in measurement of oxygen uptake due to anesthetic gases.

S J Aukburg, R T Geer, H Wollman, G R Neufeld.   

Abstract

Errors in measurement of exhaled gas volume, mixed expired oxygen and carbon dioxide concentrations, and inspired oxygen concentration and the presence of exhaled anesthetic agents cause errors in on-line calculated oxygen uptake that increase geometrically with increasing inspired oxygen concentration. No one has quantified the decrease in the magnitude of the error that might be realized if directly measured nitrogen concentration were included in the calculation. We used a computer model to evaluate this improvement, assuming an oxygen uptake of 200 ml/min and normal ventilatory parameters. Using a Monte Carlo technique, we generated 100 sets of data points, with random errors averaging 0.5% around the expected gas concentrations, and compared the accuracy of oxygen uptake calculated with and without inclusion of directly measured inspired and expired nitrogen concentrations. When the inspired oxygen fractions were 0.2, 0.5, and 0.8, the calculated oxygen uptakes +/- % standard deviation were 200 +/- 4.3, 200 +/- 12, and 196 +/- 21 when directly measured nitrogen was included versus 200 +/- 3.5, 196 +/- 16, and 205 +/- 71 when it was not. The procedure was repeated, assuming 50 ml/min of anesthetic excretion and the calculated oxygen uptakes were 200 +/- 4.6, 202 +/- 12, and 195 +/- 17 versus 212 +/- 3.8, 251 +/- 17, and 398 +/- 64. Including direct measurement of inhaled and exhaled concentrations of nitrogen or another insoluble inert tracer gas allows accurate measurement of oxygen uptake, even in the presence of exhaled anesthetic gases. It also decreases the error in oxygen uptake determination by a factor of nearly six when the inhaled oxygen fraction is 0.8.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3966669     DOI: 10.1097/00000542-198501000-00011

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  4 in total

1.  Continuous measurement of multiple inert and respiratory gas exchange in an anaesthetic breathing system by continuous indirect calorimetry.

Authors:  Christopher Stuart-Andrews; Philip Peyton; Craig Humphries; Gavin Robinson; Brian Lithgow
Journal:  J Clin Monit Comput       Date:  2009-01-24       Impact factor: 2.502

2.  Frequently repeated Fick cardiac output measurements during anesthesia.

Authors:  M Doi; K Morita; K Ikeda
Journal:  J Clin Monit       Date:  1990-04

3.  Evaluation of methods for indirect calorimetry with a ventilated lung model.

Authors:  U Braun; J Zundel; K Freiboth; W Weyland; E Turner; C F Heidelmeyer; G Hellige
Journal:  Intensive Care Med       Date:  1989       Impact factor: 17.440

4.  Comparative carbon dioxide output through injured and noninjured peritoneum during laparoscopic procedures.

Authors:  T Kazama; K Ikeda; Y Sanjo
Journal:  J Clin Monit Comput       Date:  1998-04       Impact factor: 2.502

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.