Literature DB >> 19169834

Continuous measurement of multiple inert and respiratory gas exchange in an anaesthetic breathing system by continuous indirect calorimetry.

Christopher Stuart-Andrews1, Philip Peyton, Craig Humphries, Gavin Robinson, Brian Lithgow.   

Abstract

A method was tested which permits continuous monitoring from a breathing system of the rate of uptake of multiple gas species, such as occurs in patients during inhalational anaesthesia. The method is an indirect calorimetry technique which uses fresh gas rotameters for control, regulation and measurement of the gas flows into the system, with continuous sampling of mixed exhaust gas, and frequent automated recalibration to maintain accuracy. Its accuracy was tested in 16 patients undergoing pre-cardiopulmonary bypass coronary artery surgery, breathing mixtures of oxygen/air and sevoflurane with/without nitrous oxide, by comparison with the reverse Fick method. Overall mean bias [95% confidence interval (CI)] of rate of uptake was 17.9 [7.3 to 28.5] ml min(-1) for oxygen, 0.04 [-0.42 to 0.50] ml min(-1) for sevoflurane, 10.9 [-16.1 to 37.8] for CO(2), and 8.8 [-14.8 to 32.4] ml min(-1) for nitrous oxide where present. The method proved to be accurate and precise, and allows continuous monitoring of exchange of multiple gases using standard gas analysis devices.

Entities:  

Mesh:

Year:  2009        PMID: 19169834     DOI: 10.1007/s10877-009-9161-4

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  26 in total

Review 1.  Recent advances in gas exchange measurement in intensive care patients.

Authors:  T S Walsh
Journal:  Br J Anaesth       Date:  2003-07       Impact factor: 9.166

2.  The rate of alveolar-capillary uptake of sevoflurane and nitrous oxide following anaesthetic induction.

Authors:  P J Peyton; M Fortuin; G J B Robinson; C Stuart-Andrews; R Pierce; B R Thompson
Journal:  Anaesthesia       Date:  2008-04       Impact factor: 6.955

3.  Measurement of anesthetics in blood using a conventional infrared clinical gas analyzer.

Authors:  Philip J Peyton; Michael Chong; Christopher Stuart-Andrews; Gavin J B Robinson; Robert Pierce; Bruce R Thompson
Journal:  Anesth Analg       Date:  2007-09       Impact factor: 5.108

4.  The rate of uptake of nitrous oxide in man.

Authors:  J W SEVERINGHAUS
Journal:  J Clin Invest       Date:  1954-09       Impact factor: 14.808

5.  The uptake of sevoflurane during anaesthesia.

Authors:  D A Vagts; G G Lockwood
Journal:  Anaesthesia       Date:  1998-09       Impact factor: 6.955

6.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

7.  Uptake of anaesthetic gases and vapours.

Authors:  C Y Lin
Journal:  Anaesth Intensive Care       Date:  1994-08       Impact factor: 1.669

8.  Comparison between oxygen consumption calculated by Fick's principle using a continuous thermodilution technique and measured by indirect calorimetry.

Authors:  P Bizouarn; Y Blanloeil; M Pinaud
Journal:  Br J Anaesth       Date:  1995-12       Impact factor: 9.166

9.  Continuous measurement of cardiac output by inert gas throughflow: comparison with thermodilution.

Authors:  Gavin J B Robinson; Philip J Peyton; Giuseppe M Vartuli; Rodney B Burfoot; Paul A Junor
Journal:  J Cardiothorac Vasc Anesth       Date:  2003-04       Impact factor: 2.628

10.  A comparison between the Fick method and indirect calorimetry for determining oxygen consumption in patients with fulminant hepatic failure.

Authors:  T S Walsh; P Hopton; A Lee
Journal:  Crit Care Med       Date:  1998-07       Impact factor: 7.598

View more
  2 in total

1.  In vitro performance of prefilled CO₂ absorbers with the Aisys®.

Authors:  Jan F A Hendrickx; Simon P A J De Ridder; Alexander Dehouwer; Rik Carette; Sofie De Cooman; Andre M De Wolf
Journal:  J Clin Monit Comput       Date:  2015-05-08       Impact factor: 2.502

2.  Agent consumption with the Zeus® in the automated closed circuit anesthesia mode with O2/air mixtures.

Authors:  Sofie De Cooman; Jan F A Hendrickx; Philip John Peyton; Jean-Luc Demeere; Andre M De Wolf
Journal:  BMC Res Notes       Date:  2014-07-23
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.