Literature DB >> 3966378

Radiation exposure and protection in cardiac catheterization laboratories.

S W Miller, F P Castronovo.   

Abstract

Cardiac catheterization with angiography can deliver the greatest dose of x-radiation of any diagnostic medical examination. The physicians and technologists in the angiography room receive low-level scattered radiation over a period of months to decades. Although the radiobiology is complex, the physicians who perform cardiac catheterization should be familiar with the potential genetic and somatic effects of radiation and with the methods to reduce or eliminate x-ray exposure. The aim of radiation protection criteria is to reduce the risk of cancer death to less than the fatality risk for other occupations regarded as safe. This report is a review of the literature relating to radiation exposure and protection in cardiac catheterization laboratories. Catheterization personnel have control over the time duration of exposure, placement of technologists, shielding, location of equipment and monitoring of dose received.

Entities:  

Mesh:

Year:  1985        PMID: 3966378     DOI: 10.1016/0002-9149(85)90322-4

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  5 in total

1.  Radiation exposure benefit of a lead cap in invasive cardiology.

Authors:  E Kuon; J Birkel; M Schmitt; J B Dahm
Journal:  Heart       Date:  2003-10       Impact factor: 5.994

2.  Prospectively versus retrospectively ECG-gated 256-slice coronary CT angiography: image quality and radiation dose over expanded heart rates.

Authors:  Yang Hou; Yong Yue; Wenli Guo; Guoqiang Feng; Tao Yu; Guangwei Li; Mani Vembar; Mark E Olszewski; Qiyong Guo
Journal:  Int J Cardiovasc Imaging       Date:  2010-12-14       Impact factor: 2.357

3.  Diagnosis of partial body radiation exposure in mice using peripheral blood gene expression profiles.

Authors:  Sarah K Meadows; Holly K Dressman; Pamela Daher; Heather Himburg; J Lauren Russell; Phuong Doan; Nelson J Chao; Joseph Lucas; Joseph R Nevins; John P Chute
Journal:  PLoS One       Date:  2010-07-12       Impact factor: 3.240

4.  Prospectively gated axial CT coronary angiography: preliminary experiences with a novel low-dose technique.

Authors:  Oliver Klass; Martin Jeltsch; Sebastian Feuerlein; Horst Brunner; Hans-Dieter Nagel; Matthew J Walker; Hans-Juergen Brambs; Martin H K Hoffmann
Journal:  Eur Radiol       Date:  2008-11-15       Impact factor: 5.315

5.  Prospectively gated axial CT coronary angiography: comparison of image quality and effective radiation dose between 64- and 256-slice CT.

Authors:  Oliver Klass; Matthew Walker; Anne Siebach; Tina Stuber; Sebastian Feuerlein; Markus Juchems; Martin H K Hoffmann
Journal:  Eur Radiol       Date:  2009-11-14       Impact factor: 5.315

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.