Literature DB >> 3966130

Verification and evaluation of internal flow and motion. True magnetic resonance imaging by the phase gradient modulation method.

P R Moran, R A Moran, N Karstaedt.   

Abstract

We report qualitative and quantitative evaluation and verification studies of the bipolar phase gradient modulation method for true MR imaging of internal flow and motion velocities. Velocity encoding modulations provide speed-of-motion and direction-sensitive images using special phase-sensitive reconstructions. True motion MR imaging does not depend upon subject parameters, T1 or T2, nor upon selective active-volume time-of-flight calculations, nor is it limited strictly to fluid-flow velocities. Conventional MR sequences often induce strong accidental phase gradient modulations that can cause severe artifacts in conventional MR scans and limit the useful sensitivities of true motion MR. Multiple steps of velocity encoding allow resolution of separate elements of the velocity spectrum, and enable suppression of all such phase-artifact difficulties. Some view-to-view phase inconsistencies are intrinsic to the subject being scanned, e.g., strong motion variations during the heart cycle; limitations due to such effects require external modifications in the scanning, such as cardiac gating. Since conventional density information remains in the data, independent of velocity encoding modulations, we suggest a multiple encoding sequence and saving the MR raw data. These evaluations and verifications demonstrate exciting potential in clinical application for the phase gradient modulation method of true flow and motion MR imaging.

Mesh:

Year:  1985        PMID: 3966130     DOI: 10.1148/radiology.154.2.3966130

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  14 in total

1.  Partial field-of-view spiral phase-contrast imaging using complex difference processing.

Authors:  Reza Nezafat; Richard B Thompson; J Andrew Derbyshire; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2006-09       Impact factor: 4.668

Review 2.  Cardiac magnetic resonance at high field: promises and problems.

Authors:  Ahmed M Gharib; Abdalla Elagha; Roderic I Pettigrew
Journal:  Curr Probl Diagn Radiol       Date:  2008 Mar-Apr

Review 3.  Feasibility of developing a method of imaging neuronal activity in the human brain: a theoretical review.

Authors:  D S Holder
Journal:  Med Biol Eng Comput       Date:  1987-01       Impact factor: 2.602

4.  Combination of tagging and tissue phase mapping to accelerate myocardial motion measurements in three directions.

Authors:  Anja Lutz; Jan Paul; Axel Bornstedt; Gerd Ulrich Nienhaus; Patrick Etyngier; Peter Bernhardt; Wolfgang Rottbauer; Volker Rasche
Journal:  MAGMA       Date:  2012-08-05       Impact factor: 2.310

5.  Magnetic resonance velocity mapping of 3D cerebrospinal fluid flow dynamics in hydrocephalus: preliminary results.

Authors:  Andreas Stadlbauer; Erich Salomonowitz; Christian Brenneis; Karl Ungersböck; Wilma van der Riet; Michael Buchfelder; Oliver Ganslandt
Journal:  Eur Radiol       Date:  2011-08-24       Impact factor: 5.315

Review 6.  Basic principles of magnetic resonance imaging--an update.

Authors:  A L Scherzinger; W R Hendee
Journal:  West J Med       Date:  1985-12

7.  Effects of gadolinium contrast agent on aortic blood flow and myocardial strain measurements by phase-contrast cardiovascular magnetic resonance.

Authors:  Erik Hedström; Karin Markenroth Bloch; Erik Bergvall; Freddy Ståhlberg; Håkan Arheden
Journal:  J Cardiovasc Magn Reson       Date:  2010-11-24       Impact factor: 5.364

8.  MR Quantification of Flow in Children with Vein of Galen Malformations.

Authors:  K J Poskitt; T Marotta; G Culham; S Xiang
Journal:  Interv Neuroradiol       Date:  2001-10-15       Impact factor: 1.610

9.  Magnetic resonance velocity mapping: clinical application of a new technique.

Authors:  S R Underwood; D N Firmin; R H Klipstein; R S Rees; D B Longmore
Journal:  Br Heart J       Date:  1987-05

10.  Respiratory self-gating for free-breathing abdominal phase-contrast blood flow measurements.

Authors:  Ning Jin; Robert J Lewandowski; Reed A Omary; Andrew C Larson
Journal:  J Magn Reson Imaging       Date:  2009-04       Impact factor: 4.813

View more