Literature DB >> 3963922

Venous cutdown for pacemaker implantation.

S Furman.   

Abstract

Two hundred sixty-eight dual-chamber pacemaker implants using polyurethane leads for atrium and ventricle were analyzed for the vein of entry for both atrial and ventricular leads. The cephalic vein was used for both leads in 61.2%, the external jugular vein for both leads in 8.6%, both veins in 7.8%, and the subclavian vein alone in 16.4%. The total for venous cutdown alone was 77.6%. There were no complications relevant to the vein of approach for the venous cutdown leads, but there was one pneumothorax requiring thoracic intubation for the subclavian puncture route. Venous cutdown is satisfactory for dual-chamber pacing requiring two lead systems.

Entities:  

Mesh:

Year:  1986        PMID: 3963922     DOI: 10.1016/s0003-4975(10)62705-1

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  14 in total

1.  Pre-procedure duplex ultrasonography to assist cephalic vein isolation in pacemaker and defibrillator implantation.

Authors:  Jan-Yow Chen; Kuan-Cheng Chang; Yu-Chin Lin; Hsiang-Tai Chou; Jui-Sung Hung
Journal:  J Interv Card Electrophysiol       Date:  2005-01       Impact factor: 1.900

2.  Piercing the left lung with a pacemaker lead, an uncommon complication.

Authors:  A A Hassan; J Widdershoven; M A Molenaar; J Winter
Journal:  Neth Heart J       Date:  2004-12       Impact factor: 2.380

3.  Pacemaker insertion.

Authors:  Maria Kotsakou; Ioannis Kioumis; George Lazaridis; Georgia Pitsiou; Sofia Lampaki; Antonis Papaiwannou; Anastasia Karavergou; Kosmas Tsakiridis; Nikolaos Katsikogiannis; Ilias Karapantzos; Chrysanthi Karapantzou; Sofia Baka; Ioannis Mpoukovinas; Vasilis Karavasilis; Aggeliki Rapti; Georgia Trakada; Athanasios Zissimopoulos; Konstantinos Zarogoulidis; Paul Zarogoulidis
Journal:  Ann Transl Med       Date:  2015-03

4.  Permanent pacing in patients without upper limb venous access: a review of current techniques.

Authors:  Swee-Chong Seow; Toon-Wei Lim; Devinder Singh; Wee-Tiong Yeo; Pipin Kojodjojo
Journal:  Heart Asia       Date:  2014-11-27

5.  Prospective study to develop surface landmarks for blind axillary vein puncture for permanent pacemaker and defibrillator lead implantation and compare it to available contrast venography guided technique.

Authors:  S Mehrotra; Manoj Kumar Rohit
Journal:  Indian Heart J       Date:  2015-05-13

6.  Impact of continuous quality improvement on selection of pacing mode and rate of complications in permanent pacing.

Authors:  J E Møller; E H Simonsen; M Møller
Journal:  Heart       Date:  1997-04       Impact factor: 5.994

7.  Pneumothorax resulting from subclavian puncture: a complication of permanent pacemaker lead implantation.

Authors:  J C J Res; J A de Priester; A A van Lier; C L J M van Engelen; P N A Bronzwaer; P-H Tan; M Visser
Journal:  Neth Heart J       Date:  2004-03       Impact factor: 2.380

8.  Feasibility and accuracy of pre-procedure imaging of the proximal cephalic vein by duplex ultrasonography in pacemaker and defibrillator implantation.

Authors:  Jan-Yow Chen; Kuan-Cheng Chang; Yu-Chin Lin; Hsiang-Tai Chou; Jui-Sung Hung
Journal:  J Interv Card Electrophysiol       Date:  2004-02       Impact factor: 1.900

9.  Left ventricular lead placement with over-the-wire technique for right ventricular pacing in a patient with distorted vessels.

Authors:  Ahmad Yaminisharif; Mohammad Javad Alemzadeh-Ansari; Akbar Shafiee
Journal:  Tex Heart Inst J       Date:  2013

10.  Clinical predictors of successful cephalic vein access for implantation of endocardial leads.

Authors:  Bradley P Knight; Kristen Curlett; Hakan Oral; Frank Pelosi; Fred Morady; S Adam Strickberger
Journal:  J Interv Card Electrophysiol       Date:  2002-10       Impact factor: 1.900

View more