Literature DB >> 15717155

Pre-procedure duplex ultrasonography to assist cephalic vein isolation in pacemaker and defibrillator implantation.

Jan-Yow Chen1, Kuan-Cheng Chang, Yu-Chin Lin, Hsiang-Tai Chou, Jui-Sung Hung.   

Abstract

BACKGROUND: Difficulty in isolating the cephalic vein contributes to failed pacemaker and intracardiac cardioverter-defibrillator (ICD) implantation via the cephalic venous approach. The deltopectoral groove is used as a rough landmark, but the vein is often not found here. We evaluated the benefit of pre-procedural duplex ultrasonography in isolating the cephalic vein.
METHODS: We enrolled 80 consecutive patients undergoing new pacemaker or defibrillator implantation and performed duplex ultrasonography to localize the cephalic vein before implantation. The corresponding surface location in the infraclavicular region and the depth of the cephalic vein were identified and recorded if the vein was well visualized. Using the imaging results, we dissected the skin over the predicted location until the cephalic vein was isolated. We determined the depth and corresponding surface location of the proximal cephalic vein during surgery. Afterward, we compared localization of the vein using imaging, surgery, and the deltopectoral-groove method. The relationship between cephalic vein depth and body parameters was also evaluated after the procedure.
RESULTS: All proximal cephalic veins were successfully isolated under the assistance of pre-procedural duplex ultrasonography. When the corresponding surface locations were compared, the location depicted on sonograms was closer to the surgical finding than the location determined by using the deltopectoral-groove method (0.5 +/- 3.9 vs. 4.9 +/- 9.6 mm; P < .001). The depth of the cephalic vein derived from duplex sonograms showed excellent correlation with the surgical findings (r = 0.93, P < 0.001). The cephalic vein depth and body mass index (BMI) also showed a linear relationship with good correlation (r = 0.70, P < 0.001).
CONCLUSION: Pre-procedural duplex ultrasonography helped in localizing the proximal cephalic vein and isolating the cephalic vein. Surface localization of the proximal cephalic vein was superior with sonography than with the deltopectoral-groove method. There was a linear relationship with good correlation between BMI and cephalic vein depth.

Entities:  

Mesh:

Year:  2005        PMID: 15717155     DOI: 10.1007/s10840-005-5844-z

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  23 in total

1.  Ultrasonography of the femoral vessels in the groin: implications for vascular access.

Authors:  P Hughes; C Scott; A Bodenham
Journal:  Anaesthesia       Date:  2000-12       Impact factor: 6.955

2.  Ultrasound measurements of overlying soft tissue thickness at four skeletal sites suitable for in vivo x-ray fluorescence.

Authors:  A Pejović-Milić; J A Brito; J Gyorffy; D R Chettle
Journal:  Med Phys       Date:  2002-11       Impact factor: 4.071

3.  Prospective validation of an algorithm to maximize native arteriovenous fistulae for chronic hemodialysis access.

Authors:  Thomas S Huber; C Keith Ozaki; Timothy C Flynn; W Anthony Lee; Scott A Berceli; Christa M Hirneise; Lori M Carlton; Jeffrey W Carter; Edward A Ross; James M Seeger
Journal:  J Vasc Surg       Date:  2002-09       Impact factor: 4.268

4.  Modified cephalic vein guide wire technique for permanent pacemaker implantation.

Authors:  S K Dwivedi; V S Narain; S Dhawan; D Soni; M Hasan
Journal:  Indian Heart J       Date:  1992 Mar-Apr

5.  Venous cutdown for pacemaker implantation.

Authors:  S Furman
Journal:  Ann Thorac Surg       Date:  1986-04       Impact factor: 4.330

6.  Sites of stenosis in AV fistulae for haemodialysis access.

Authors:  S Sivanesan; T V How; A Bakran
Journal:  Nephrol Dial Transplant       Date:  1999-01       Impact factor: 5.992

7.  Feasibility and accuracy of pre-procedure imaging of the proximal cephalic vein by duplex ultrasonography in pacemaker and defibrillator implantation.

Authors:  Jan-Yow Chen; Kuan-Cheng Chang; Yu-Chin Lin; Hsiang-Tai Chou; Jui-Sung Hung
Journal:  J Interv Card Electrophysiol       Date:  2004-02       Impact factor: 1.900

8.  Subclavian venous catheterization: greater success rate for less experienced operators using ultrasound guidance.

Authors:  E Gualtieri; S A Deppe; M E Sipperly; D R Thompson
Journal:  Crit Care Med       Date:  1995-04       Impact factor: 7.598

9.  Diagnosis of deep venous thrombosis. A prospective study comparing duplex scanning to contrast venography.

Authors:  L A Killewich; G R Bedford; K W Beach; D E Strandness
Journal:  Circulation       Date:  1989-04       Impact factor: 29.690

10.  Clinical predictors of successful cephalic vein access for implantation of endocardial leads.

Authors:  Bradley P Knight; Kristen Curlett; Hakan Oral; Frank Pelosi; Fred Morady; S Adam Strickberger
Journal:  J Interv Card Electrophysiol       Date:  2002-10       Impact factor: 1.900

View more
  1 in total

1.  Pacemaker placement and shoulder surgery: is there a risk?

Authors:  P M Ahrens; N A Siddiqui; R D Rakhit
Journal:  Ann R Coll Surg Engl       Date:  2012-01       Impact factor: 1.891

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.