The cases of two patients with delayed paraplegia after segmental spinal instrumentation with sublaminar wiring are reported. Both patients had complex spinal deformities and had transient neural deficits after the first-stage procedure of anterior release and spine fusion. They had uneventful spinal-cord monitoring during the second-stage procedure of posterior instrumentation and fusion, and function of the lower extremities was present immediately after that operation. Paraplegia then ensued, and was recognized thirty hours later in one patient and six days later in the other. Considering our reproducible and reliable experience (no false-negative results) with spinal cord monitoring in 307 operations, we propose that the delayed onset of paraplegia resulted from a progression of ischemic and edema-producing events that had not developed sufficiently intraoperatively to be reflected by the monitoring. The paraplegia became evident only when the subarachnoid space was obstructed because of progressive postoperative neural edema. The presence of sublaminar implants in narrow, kyphotic segments of the spinal canal probably exacerbated the neural irritation by dural impingement, which was seen myelographically.

Entities:  

Mesh:

Year:  1986        PMID: 3957979

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  6 in total

1.  Spinal cord compression caused by the rod of a Harrington instrumentation device: a late complication in scoliosis surgery.

Authors:  A Krödel; J C Rehmet; C Hamburger
Journal:  Eur Spine J       Date:  1997       Impact factor: 3.134

2.  Anterior spinal artery ischemia syndrome--a possible complication following surgery for the correction of scoliosis.

Authors:  H P Li; J N Zhou
Journal:  J Tongji Med Univ       Date:  1988

3.  Comparing Mersilene* tape and stainless steel wire as sublaminar spinal fixation in the Chagma baboon (Papio ursinus).

Authors:  L J Grobler; R W Gaines; P G Kempff
Journal:  Iowa Orthop J       Date:  1997

4.  Delayed neurological deterioration with an unknown cause subsequent to surgery for intraspinal meningiomas.

Authors:  Tao Yang; Liang Wu; Xiaofeng Deng; Chenlong Yang; Yan Zhang; Dong Zhang; Yulun Xu
Journal:  Oncol Lett       Date:  2015-03-10       Impact factor: 2.967

5.  Biomechanical evaluation of a new fixation device for the thoracic spine.

Authors:  Michio Hongo; Brice Ilharreborde; Ralph E Gay; Chunfeng Zhao; Kristin D Zhao; Lawrence J Berglund; Mark Zobitz; Kai-Nan An
Journal:  Eur Spine J       Date:  2009-04-29       Impact factor: 3.134

6.  Hybrid Stabilization of Thoracic Spine Fractures with Sublaminar Bands and Transpedicular Screws: Description of a Surgical Alternative and Review of the Literature.

Authors:  Marie-Therese Unterweger; Frank Kandziora; Klaus J Schnake
Journal:  Case Rep Orthop       Date:  2015-11-16
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.