Literature DB >> 3898441

A new synthetic monofilament absorbable suture made from polytrimethylene carbonate.

A R Katz, D P Mukherjee, A L Kaganov, S Gordon.   

Abstract

The physical and biologic characteristics of a new synthetic absorbable monofilament suture, glycolide trimethylene carbonate (GTMC) are presented. The suture was formulated to combine predictable in vivo performance of synthetic absorbable sutures with the handling characteristics of a monofilament suture. Three in vivo studies were described: strength, gross and microscopic absorption and reaction, and radiolabelled decay. The studies carried out in rats showed cumulative strength retention of sizes 0, 00, 4-0 and 5-0 of 81 per cent at 14 days, 59 per cent at 28 days and 30 per cent at 42 days. Strength retention was consistent throughout the size spectrum. Absorption of sizes 00 and 4-0 were studied in subcutaneous implantations in rabbits. Histologic assessment of absorption obtained from serial sections at intervals of three to nine months showed that, in both sizes, complete absorption occurred between six and seven months. At six months, 83 per cent of size 00 was absorbed and size 4-0 was 93 per cent absorbed. At seven months, no implanted material was discernible histologically. Untoward tissue reactions, such as acute inflammatory cells, abscesses or tissue necrosis, were not observed. There were no signs of cellular mobilization of any kind observed remote from the implant. Absorption of GTMC sutures was achieved through the action of mononuclear and multinuclear macrophages which were confined to the implant and sequestered by a fibrous connective tissue capsule. When implant absorption was complete, resorbtion of the macrophage component was observed which was replaced by a narrow cord of fibrous tissue and collagen. The results of studies of radiolabelled sutures carried out in the subcutaneous tissues of rats revealed urine and expired CO2 to be the major excretary routes of the metabolites. By 22 to 24 weeks, 0.1 to 0.7 per cent of the total implanted radioactivity remained at the suture sites. Tissue deposition and excretion of radioactivity suggests similar metabolism of the sutures in both species. We conclude that GTMC sutures maintain good strength with little or no absorption during the critical wound healing period, absorbs completely from tissues in six to seven months with minimal tissue reaction and, therefore, provides an absorbable, flexible, monofilament material with extended support that is strong and effective.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3898441

Source DB:  PubMed          Journal:  Surg Gynecol Obstet        ISSN: 0039-6087


  15 in total

Review 1.  Techniques for colorectal anastomosis.

Authors:  Yik Hong Ho; Mohamed Ahmed Tawfik Ashour
Journal:  World J Gastroenterol       Date:  2010-04-07       Impact factor: 5.742

2.  Treatment of high ano-vaginal fistula with GORE BIO-A ® Fistula Plug in an immunocompromised patient.

Authors:  G A Binda; A Piscitelli; R Longhin
Journal:  Tech Coloproctol       Date:  2012-11-27       Impact factor: 3.781

3.  Pelvic reconstruction after abdominoperineal resection: a pilot study using an absorbable synthetic prosthesis.

Authors:  C Moreno-Sanz; M Manzanera-Díaz; F J Cortina-Oliva; J de Pedro-Conal; M Clerveus; J Picazo-Yeste
Journal:  Tech Coloproctol       Date:  2011-09-29       Impact factor: 3.781

4.  Perioperative outcome of laparoscopic left lateral liver resection is improved by using staple line reinforcement technique: a case report.

Authors:  Esther C J Consten; Michel Gagner
Journal:  J Gastrointest Surg       Date:  2005-03       Impact factor: 3.452

5.  Physical properties of high molecular weight 1,3-trimethylene carbonate and D,L-lactide copolymers.

Authors:  Ana Paula Pêgo; André A Poot; Dirk W Grijpma; Jan Feijen
Journal:  J Mater Sci Mater Med       Date:  2003-09       Impact factor: 3.896

6.  Absorbable mesh reinforcement of a stapled pancreatic transection line reduces the leak rate with distal pancreatectomy.

Authors:  Reuben I Thaker; Brent D Matthews; David C Linehan; Steven M Strasberg; J Chris Eagon; William G Hawkins
Journal:  J Gastrointest Surg       Date:  2007-01       Impact factor: 3.452

7.  Thermal stability and melt rheology of poly(p-dioxanone).

Authors:  Changdeng Liu; Sasa Andjelić; Jack Zhou; Yunmei Xu; Christophe Vailhe; Robert Vetrecin
Journal:  J Mater Sci Mater Med       Date:  2008-07-03       Impact factor: 3.896

8.  Use of absorbable sutures in canine carotid arteries.

Authors:  A R Rey; J Carrillo-Farga; C O Velasco; M O Valencia
Journal:  Tex Heart Inst J       Date:  1990

9.  A comparison of gastrojejunal anastomoses with or without buttressing in a porcine model.

Authors:  William W Hope; Marc Zerey; Thomas M Schmelzer; William L Newcomb; B Lauren Paton; Jessica J Heath; Richard D Peindl; H James Norton; Amy E Lincourt; B Todd Heniford; Keith S Gersin
Journal:  Surg Endosc       Date:  2008-10-02       Impact factor: 4.584

10.  Perioperative outcome of laparoscopic left lateral liver resection is improved by using a bioabsorbable staple line reinforcement material in a porcine model.

Authors:  Esther C J Consten; Gregory F Dakin; Jan-Lukas Robertus; Sergio Bardaro; Luca Milone; Michel Gagner
Journal:  Surg Endosc       Date:  2008-02-01       Impact factor: 4.584

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.