Literature DB >> 15749597

Perioperative outcome of laparoscopic left lateral liver resection is improved by using staple line reinforcement technique: a case report.

Esther C J Consten1, Michel Gagner.   

Abstract

Current laparoscopic stapling technology still cannot prevent bile leakage (<55%) along the resection margin. A new staple line reinforcement technique was used in the present case. This technique incorporates an absorbable polymer membrane into the stapler system, such that it buttresses the transected solid organ. The objectives of this novel procedure are to decrease hemorrhage at the staple line and to prevent bile duct leakage after liver resection. A 47-year-old man followed for status post biliopancreatic diversion with duodenal switch presented with epigastric pain. On imaging, he was found to have a lesion in segment 2-3 of the left lobe of the liver, which measured at least 3 cm in diameter. He was admitted to the hospital to undergo a laparoscopic left lateral liver resection. This procedure involved laparoscopic ultrasonography of the liver and transection of the left liver lobe with endoscopic linear staplers. The staple height of 3.5, 60 mm long, reinforced with an absorbable polymer membrane was used for liver transection to catch the portal branches. This required multiple firings in the liver parenchyma and additional division of some tissue using the Harmonic scalpel. The larger branch in the middle of segment 2-3 and the left hepatic vein were both transected with the novel staple line reinforcement technique. Bleeding or any bile leakage in this area could not be visualized. No drains were left. The patient's postoperative course was uncomplicated, and he was discharged on postoperative day 3. Pathology results showed a cavernous hemangioma of 4.5 cm in diameter. Staple line reinforcement with the absorbable polymer membrane has the potential to decrease staple line hemorrhage and bile leakage.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15749597     DOI: 10.1016/j.gassur.2004.07.016

Source DB:  PubMed          Journal:  J Gastrointest Surg        ISSN: 1091-255X            Impact factor:   3.452


  27 in total

1.  Surgical staple metalloptysis after apical bullectomy: a reaction to bovine pericardium?

Authors:  Mohammed F Shamji; Donna E Maziak; Farid M Shamji; Frederick R K Matzinger; D Garth Perkins
Journal:  Ann Thorac Surg       Date:  2002-07       Impact factor: 4.330

2.  Surgically staged focal liver lesions: accuracy and reproducibility of dual-phase helical CT for detection and characterization.

Authors:  Ihab R Kamel; Michael A Choti; Karen M Horton; H J V Braga; Bernard A Birnbaum; Elliot K Fishman; Richard E Thompson; David A Bluemke
Journal:  Radiology       Date:  2003-06       Impact factor: 11.105

3.  Comparison of strength properties of poly-L/D-lactide (PLDLA) 96/4 and polyglyconate (Maxon) sutures: in vitro, in the subcutis, and in the achilles tendon of rabbits.

Authors:  J Kangas; S Paasimaa; P Mäkelä; J Leppilahti; P Törmälä; T Waris; N Ashammakhi
Journal:  J Biomed Mater Res       Date:  2001

4.  Laboratory evaluation of four techniques of stapled gastroplasty.

Authors:  R E Brolin
Journal:  Surgery       Date:  1985-01       Impact factor: 3.982

Review 5.  Laparoscopic enucleation of insulinoma in the pancreas: case report and review of the literature.

Authors:  M Furihata; N Tagaya; K Kubota
Journal:  Surg Laparosc Endosc Percutan Tech       Date:  2001-08       Impact factor: 1.719

6.  Staple-line reinforcement with a new type of polyglycolic acid felt.

Authors:  M Kawamura; K Kase; M Sawafuji; M Watanabe; H Horinouchi; K Kobayashi
Journal:  Surg Laparosc Endosc Percutan Tech       Date:  2001-02       Impact factor: 1.719

7.  Laparoscopy with laparoscopic ultrasound for pretreatment staging of hepatocellular carcinoma: a prospective study.

Authors:  M Montorsi; R Santambrogio; P Bianchi; E Opocher; G P Cornalba; G Dapri; L Bonavina; M Zuin; M Podda
Journal:  J Gastrointest Surg       Date:  2001 May-Jun       Impact factor: 3.452

8.  Possibilities of laparoscopic liver resection.

Authors:  J Mouiel; N Katkhouda; J Gugenheim; P Fabiani
Journal:  J Hepatobiliary Pancreat Surg       Date:  2000

9.  Laparoscopic liver resection of benign liver tumors.

Authors:  B Descottes; D Glineur; F Lachachi; D Valleix; J Paineau; A Hamy; M Morino; H Bismuth; D Castaing; E Savier; P Honore; O Detry; M Legrand; J S Azagra; M Goergen; M Ceuterick; J Marescaux; D Mutter; B de Hemptinne; R Troisi; J Weerts; B Dallemagne; C Jehaes; M Gelin; V Donckier; R Aerts; B Topal; C Bertrand; B Mansvelt; L Van Krunckelsven; D Herman; M Kint; E Totte; R Schockmel; J F Gigot
Journal:  Surg Endosc       Date:  2002-10-08       Impact factor: 4.584

Review 10.  Late complication of bovine pericardium patches used for lung volume reduction surgery.

Authors:  Steeve Provencher; Jean Deslauriers
Journal:  Eur J Cardiothorac Surg       Date:  2003-06       Impact factor: 4.191

View more
  5 in total

1.  Laparoscopic hepatic left lateral lobectomy combined with fiber choledochoscopic exploration of the common bile duct and traditional open operation.

Authors:  Kun Zhang; Shao-Geng Zhang; Yi Jiang; Peng-Fen Gao; Hai-Ying Xie; Zhi-Hong Xie
Journal:  World J Gastroenterol       Date:  2008-02-21       Impact factor: 5.742

2.  Buttressing staples with cholecyst-derived extracellular matrix (CEM) reinforces staple lines in an ex vivo peristaltic inflation model.

Authors:  Krishna Burugapalli; Jeffrey C Y Chan; John L Kelly; Abhay Pandit
Journal:  Obes Surg       Date:  2008-05-06       Impact factor: 4.129

3.  Laparoscopic liver resection using radiofrequency coagulation.

Authors:  D Hompes; R Aerts; F Penninckx; B Topal
Journal:  Surg Endosc       Date:  2006-11-21       Impact factor: 4.584

Review 4.  Application of stapling devices in liver surgery: Current status and future prospects.

Authors:  Dian-Bo Yao; Shuo-Dong Wu
Journal:  World J Gastroenterol       Date:  2016-08-21       Impact factor: 5.742

5.  Absorbable mesh reinforcement of a stapled pancreatic transection line reduces the leak rate with distal pancreatectomy.

Authors:  Reuben I Thaker; Brent D Matthews; David C Linehan; Steven M Strasberg; J Chris Eagon; William G Hawkins
Journal:  J Gastrointest Surg       Date:  2007-01       Impact factor: 3.452

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.