External noninvasive temporary cardiac pacing: clinical trials.

P M Zoll, R H Zoll, R H Falk, J E Clinton, D R Eitel, E M Antman.   

Abstract

An external cardiac pacemaker-monitor has been developed that provides safe, effective noninvasive ventricular stimulation that is well tolerated in conscious patients and allows clear recognition of electrocardiographic response. The noninvasive temporary pacemaker (NTP) has now been applied in 134 patients in five hospitals. Stimulation was tolerated well in 73 of 82 conscious patients, and nine found it intolerable. The NTP was effective in evoking electrocardiographic responses in 105 patients; the 29 failures were in the presence of prolonged hypoxia or severe discomfort. The NTP was clinically useful in 82 patients: 43 of 86 were resuscitated from emergency or expected arrest, 38 of 40 were maintained in standby readiness for up to 1 month but did not require stimulation, and one of eight patients with tachycardia obtained some clinical benefit. The NTP was especially useful in 25 patients with complications or contraindications to endocardial pacing and in 57 patients in whom insertion of an endocardial electrode was avoided.

Entities:  

Mesh:

Year:  1985        PMID: 3886190     DOI: 10.1161/01.cir.71.5.937

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  10 in total

Review 1.  Temporary cardiac pacing.

Authors:  M D Gammage
Journal:  Heart       Date:  2000-06       Impact factor: 5.994

2.  Problems with temporary cardiac pacing. Expecting trainees in medicine to perform transvenous pacing is no longer acceptable.

Authors:  J J Murphy
Journal:  BMJ       Date:  2001-09-08

3.  Dysrhythmias in acute myocardial infarction: how to treat, when to treat, and when not to treat.

Authors:  J A Lopez; A Massumi
Journal:  Tex Heart Inst J       Date:  1992

4.  Measurement of regional cardiac fibrillation thresholds.

Authors:  O Z Roy; B J Trollope; J R Scott
Journal:  Med Biol Eng Comput       Date:  1987-03       Impact factor: 2.602

5.  Successful transcutaneous external pacing for asystole following cardiac arrest.

Authors:  S S Tachakra; E Jepson; M W Beckett; R Barrie
Journal:  Arch Emerg Med       Date:  1988-09

6.  A transient, closed-loop network of wireless, body-integrated devices for autonomous electrotherapy.

Authors:  Yeon Sik Choi; Hyoyoung Jeong; Rose T Yin; Raudel Avila; Anna Pfenniger; Jaeyoung Yoo; Jong Yoon Lee; Andreas Tzavelis; Young Joong Lee; Sheena W Chen; Helen S Knight; Seungyeob Kim; Hak-Young Ahn; Grace Wickerson; Abraham Vázquez-Guardado; Elizabeth Higbee-Dempsey; Bender A Russo; Michael A Napolitano; Timothy J Holleran; Leen Abdul Razzak; Alana N Miniovich; Geumbee Lee; Beth Geist; Brandon Kim; Shuling Han; Jaclyn A Brennan; Kedar Aras; Sung Soo Kwak; Joohee Kim; Emily Alexandria Waters; Xiangxing Yang; Amy Burrell; Keum San Chun; Claire Liu; Changsheng Wu; Alina Y Rwei; Alisha N Spann; Anthony Banks; David Johnson; Zheng Jenny Zhang; Chad R Haney; Sung Hun Jin; Alan Varteres Sahakian; Yonggang Huang; Gregory D Trachiotis; Bradley P Knight; Rishi K Arora; Igor R Efimov; John A Rogers
Journal:  Science       Date:  2022-05-26       Impact factor: 63.714

Review 7.  Cardiac pacing in the accident and emergency department: a review.

Authors:  J Heyworth
Journal:  J R Soc Med       Date:  1988-07       Impact factor: 18.000

8.  A review of temporary cardiac pacing wires.

Authors:  Peter McCann
Journal:  Indian Pacing Electrophysiol J       Date:  2007-01-01

9.  Fully implantable and bioresorbable cardiac pacemakers without leads or batteries.

Authors:  Yeon Sik Choi; Rose T Yin; Anna Pfenniger; Jahyun Koo; Raudel Avila; K Benjamin Lee; Sheena W Chen; Geumbee Lee; Gang Li; Yun Qiao; Alejandro Murillo-Berlioz; Alexi Kiss; Shuling Han; Seung Min Lee; Chenhang Li; Zhaoqian Xie; Yu-Yu Chen; Amy Burrell; Beth Geist; Hyoyoung Jeong; Joohee Kim; Hong-Joon Yoon; Anthony Banks; Seung-Kyun Kang; Zheng Jenny Zhang; Chad R Haney; Alan Varteres Sahakian; David Johnson; Tatiana Efimova; Yonggang Huang; Gregory D Trachiotis; Bradley P Knight; Rishi K Arora; Igor R Efimov; John A Rogers
Journal:  Nat Biotechnol       Date:  2021-06-28       Impact factor: 68.164

10.  A randomized controlled feasibility trial comparing safety and effectiveness of prehospital pacing versus conventional treatment: 'PrePACE'.

Authors:  Laurie J Morrison; Jennifer Long; Marian Vermeulen; Brian Schwartz; Bruce Sawadsky; Jamie Frank; Bruce Cameron; Robert Burgess; Jennifer Shield; Paul Bagley; Vivien Mausz; James E Brewer; Paul Dorian
Journal:  Resuscitation       Date:  2007-10-22       Impact factor: 5.262