Literature DB >> 3838226

Banded intracochlear electrode array: evaluation of insertion trauma in human temporal bones.

R K Shepherd, G M Clark, B C Pyman, R L Webb.   

Abstract

A banded free-fit scala tympani array was inserted into the basal turn of nine human cochleas to evaluate the trauma produced by the procedure. These nine cochleas, together with five nonimplanted controls, were serially sectioned and examined microscopically for damage to the membranous labyrinth, in particular the spiral ligament, the basilar and Reissner's membranes, the stria vascularis, and the osseous spiral lamina. The severity and location of any trauma along the cochlear spiral were recorded. The results indicate that the insertion of the banded scala tympani array resulted in minimal mechanical damage, occurring primarily to a localized region of the spiral ligament. This would not result in significant neural degeneration, and therefore would not compromise the efficacy of the multichannel cochlear prosthesis.

Entities:  

Mesh:

Year:  1985        PMID: 3838226     DOI: 10.1177/000348948509400112

Source DB:  PubMed          Journal:  Ann Otol Rhinol Laryngol        ISSN: 0003-4894            Impact factor:   1.547


  16 in total

Review 1.  The multiple-channel cochlear implant: the interface between sound and the central nervous system for hearing, speech, and language in deaf people-a personal perspective.

Authors:  Graeme M Clark
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  2006-05-29       Impact factor: 6.237

2.  Across-site variation in detection thresholds and maximum comfortable loudness levels for cochlear implants.

Authors:  Bryan E Pfingst; Li Xu
Journal:  J Assoc Res Otolaryngol       Date:  2003-11-20

3.  Intra-Operative Neural Response Telemetry and Acoustic Reflex Assessment using an Advance-In-Stylet Technique and Modiolus-Hugging: A prospective cohort study.

Authors:  Abdulrahman Hagr
Journal:  Sultan Qaboos Univ Med J       Date:  2011-08-15

Review 4.  The development of the Nucleus Freedom Cochlear implant system.

Authors:  James F Patrick; Peter A Busby; Peter J Gibson
Journal:  Trends Amplif       Date:  2006-12

5.  Considerations for design of future cochlear implant electrode arrays: electrode array stiffness, size, and depth of insertion.

Authors:  Stephen J Rebscher; Alexander Hetherington; Ben Bonham; Peter Wardrop; David Whinney; Patricia A Leake
Journal:  J Rehabil Res Dev       Date:  2008

6.  Miniature pigs: a large animal model of cochlear implantation.

Authors:  Haijin Yi; Weiwei Guo; Wei Chen; Lei Chen; Jingying Ye; Shiming Yang
Journal:  Am J Transl Res       Date:  2016-12-15       Impact factor: 4.060

7.  Round window versus cochleostomy technique in cochlear implantation: histologic findings.

Authors:  Céline Richard; Jose N Fayad; Joni Doherty; Fred H Linthicum
Journal:  Otol Neurotol       Date:  2012-09       Impact factor: 2.311

8.  Development of a surgical approach for a wide-view suprachoroidal retinal prosthesis: evaluation of implantation trauma.

Authors:  Joel Villalobos; Penelope J Allen; Mark F McCombe; Meera Ulaganathan; Ehud Zamir; David C Ng; Robert K Shepherd; Chris E Williams
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-08-27       Impact factor: 3.117

9.  The development of neural stimulators: a review of preclinical safety and efficacy studies.

Authors:  Robert K Shepherd; Joel Villalobos; Owen Burns; David A X Nayagam
Journal:  J Neural Eng       Date:  2018-05-14       Impact factor: 5.379

10.  Role of electrode placement as a contributor to variability in cochlear implant outcomes.

Authors:  Charles C Finley; Timothy A Holden; Laura K Holden; Bruce R Whiting; Richard A Chole; Gail J Neely; Timothy E Hullar; Margaret W Skinner
Journal:  Otol Neurotol       Date:  2008-10       Impact factor: 2.311