J Møgelvang, C Thomsen, J Mehlsen, G Bräckle, M Stubgaard, O Henriksen.
Abstract
Left ventricular end-diastolic and end-systolic volumes were determined in 17 patients with different levels of left ventricular function by magnetic resonance imaging (MRI). A 1.5 Tesla Magnet was used obtaining ECG triggered single and multiple slices. Calculated cardiac outputs were compared with those measured simultaneously by a classical physiological indicator dilution technique. There was good agreement between cardiac output as measured by MRI and the indicator dilution method, when the multislice technique was used (r = 0.87, p less than 0.001). A poor correlation between the two methods was seen when the single slice technique was used (r = 0.06, p greater than 0.80). The results indicate that MRI is a reliable method for left ventricular volume determination when the multislice technique is used.Entities:
Mesh:
Year: 1986 PMID: 3830200 DOI: 10.1093/oxfordjournals.eurheartj.a062010
Source DB: PubMed Journal: Eur Heart J ISSN: 0195-668X Impact factor: 29.983