Literature DB >> 15682287

Accuracy of short-axis cardiac MRI automatically derived from scout acquisitions in free-breathing and breath-holding modes.

M G Danilouchkine1, J J M Westenberg, B P F Lelieveldt, J H C Reiber.   

Abstract

To qualitatively assess the accuracy of automated cardiovascular magnetic resonance planning procedures devised from scout acquisitions in free-breathing and breath-holding modes, to quantitatively evaluate the accuracy of the derived left ventricular volumes, mass and function and compare these parameters with the ones obtained from the manually planned acquisitions. Ten healthy volunteers underwent cardiovascular MR (CMR) acquisitions for ventricular function assessment. Short-axis data sets of the left ventricle (LV) were manually planned and generated twice in an automatic fashion. Automated planning parameters were derived from gated scout acquisitions in free-breathing and breath-holding modes. End-diastolic volume (EDV), end-systolic volume (ESV), ejection fraction (EF), and left ventricular mass (LVM) were measured. The agreement between the manual and automatic planning methods, as well as the variability of the aforementioned measurements were assessed. The differences between two automated planning methods were also compared. The mean differences between the manual and automated CMR planning derived from gated scouts in free-breathing mode were 8.05 ml (EDV), 1.84 ml (ESV), 0.69% (EF), and 4.72 g (LVM). The comparison between manual and automated CMR planning derived from gated scouts in breath-holding mode yielded the following differences: 4.22 ml (EDV), 0.34 ml (ESV), 0.3% (EF), and -0.72 mg (LVM). The variability coefficients were 3.72 and 3.66 (EDV), 5.6 and 8.19 (ESV), 3.46 and 4.31 (EF), 6.49 and 5.20 (LVM) for the automated CMR planning methods derived from scouts in free-breathing and breath-holding modes, respectively. Automated CMR planning methods can provide accurate measurements of LV dimensions in normal subjects, and therefore may be utilized in the clinical environment to provide a cost-effective solution for functional assessment of the human cardiovascular system.

Entities:  

Mesh:

Year:  2005        PMID: 15682287     DOI: 10.1007/s10334-004-0073-5

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  23 in total

1.  3-D freehand echocardiography for automatic left ventricle reconstruction and analysis based on multiple acoustic windows.

Authors:  Xujiong Ye; J Alison Noble; David Atkinson
Journal:  IEEE Trans Med Imaging       Date:  2002-09       Impact factor: 10.048

2.  Efficient model-based quantification of left ventricular function in 3-D echocardiography.

Authors:  Olivier Gérard; Antoine Collet Billon; Jean-Michel Rouet; Marie Jacob; Maxim Fradkin; Cyril Allouche
Journal:  IEEE Trans Med Imaging       Date:  2002-09       Impact factor: 10.048

Review 3.  Quantitative analysis of cardiovascular MR images.

Authors:  R J van der Geest; A de Roos; E E van der Wall; J H Reiber
Journal:  Int J Card Imaging       Date:  1997-06

4.  Biventricular function in patients with nonischemic right ventricle tachyarrhythmias assessed with MR imaging.

Authors:  H W Kayser; M J Schalij; E E van der Wall; B C Stoel; A de Roos
Journal:  AJR Am J Roentgenol       Date:  1997-10       Impact factor: 3.959

5.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

6.  Oblique views in magnetic resonance imaging of the heart by combined axial rotations.

Authors:  A C Van Rossum; F C Visser; M J Van Eenige; J Valk; J P Roos
Journal:  Acta Radiol       Date:  1987 Sep-Oct       Impact factor: 1.990

7.  Left ventricular quantification with breath-hold MR imaging: comparison with echocardiography.

Authors:  J G Bogaert; H T Bosmans; F E Rademakers; E P Bellon; M C Herregods; J A Verschakelen; F Van de Werf; G J Marchal
Journal:  MAGMA       Date:  1995-03       Impact factor: 2.310

8.  Left ventricular measurements with cine and spin-echo MR imaging: a study of reproducibility with variance component analysis.

Authors:  P M Pattynama; H J Lamb; E A van der Velde; E E van der Wall; A de Roos
Journal:  Radiology       Date:  1993-04       Impact factor: 11.105

9.  Measurement of left ventricular volume after anterior myocardial infarction: comparison of magnetic resonance imaging, echocardiography, and radionuclide ventriculography.

Authors:  K H Darasz; S R Underwood; J Bayliss; S M Forbat; J Keegan; P A Poole-Wilson; G C Sutton; D Pennell
Journal:  Int J Cardiovasc Imaging       Date:  2002-04       Impact factor: 2.357

10.  Magnetic resonance imaging of the heart using image planes oriented to cardiac axes: experience with 100 cases.

Authors:  R E Dinsmore; G L Wismer; S W Miller; R Thompson; D L Johnston; P Liu; R D Okada; S Saini; T J Brady
Journal:  AJR Am J Roentgenol       Date:  1985-12       Impact factor: 3.959

View more
  1 in total

1.  Automatic localization of the left ventricle from cardiac cine magnetic resonance imaging: a new spectrum-based computer-aided tool.

Authors:  Liang Zhong; Jun-Mei Zhang; Xiaodan Zhao; Ru San Tan; Min Wan
Journal:  PLoS One       Date:  2014-04-10       Impact factor: 3.240

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.