Literature DB >> 3763924

Digital radiographic imaging system with multiple-slit scanning x-ray beam: preliminary report.

K Doi, H Fujita, K Ohara, K Ono, H Matsui, M L Giger, H P Chan.   

Abstract

A digital imaging system that employs a novel scanning x-ray tube, a multiple-slit assembly (MSA), and an image intensifier (II)-TV digital system is described. Use of the MSA can increase x-ray utilization by a factor of 100 over that obtained with single-slit systems. Scatter and veiling glare can be reduced substantially by synthesizing the final image from a number of multiple-slit images, resulting in improvement in contrast sensitivity. An experimental prototype system consisted of a conventional x-ray tube and an II-TV digital system used in conjunction with mechanical scanning of the MSA. Attenuation curves measured with an aluminum stepwedge showed that scatter and veiling glare were eliminated by this approach. Reconstructed images of phantoms were superior to images obtained with conventional wide-beam exposure. Physical parameters related to design of the scanning x-ray tube and a digital system for acquiring images of the chest are discussed.

Mesh:

Year:  1986        PMID: 3763924     DOI: 10.1148/radiology.161.2.3763924

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  4 in total

Review 1.  Literature review: picture archiving and communication system.

Authors:  U P Schmiedl; A H Rowberg
Journal:  J Digit Imaging       Date:  1990-11       Impact factor: 4.056

2.  Scatter rejection and low-contrast performance of a slot-scan digital chest radiography system with electronic aft-collimation: a chest phantom study.

Authors:  Xinming Liu; Chris C Shaw; Chao-Jen Lai; Mustafa C Altunbas; Lingyun Chen; Tao Han; Tianpeng Wang
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

3.  Comparison of scatter rejection and low-contrast performance of scan equalization digital radiography (SEDR), slot-scan digital radiography, and full-field digital radiography systems for chest phantom imaging.

Authors:  Xinming Liu; Chris C Shaw; Chao-Jen Lai; Tianpeng Wang
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

4.  A unified scatter rejection and correction method for cone beam computed tomography.

Authors:  Cem Altunbas; Yeonok Park; Zhelin Yu; Anant Gopal
Journal:  Med Phys       Date:  2021-02-06       Impact factor: 4.071

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.