Literature DB >> 3747820

Counter rotating current local coils for high-resolution magnetic resonance imaging.

W Froncisz, A Jesmanowicz, J B Kneeland, J S Hyde.   

Abstract

A type of local coil (or surface coil) for magnetic resonance imaging and spectroscopy is described in which two circular loops of the same diameter are disposed axially with respect to each other and in which counter rotating currents (CRC) are supported in the two loops. This type of coil has been used for localized reception in a uniform circularly polarized excitation field produced by a whole-body coil of an imager functioning at 1.5 T. The CRC coil is decoupled from the transmitter coil by a combination of intrinsic (or geometrical) isolation (which functions during both excitation and reception) plus passive decoupling (which functions only during excitation). CRC coils of 7.5, 10, 12.5, and 15 cm diameter have been compared on a bench test setup with conventional surface coils of these diameters. Sensitivities are very similar. Q's have been measured as a function of coil diameter and both Q's and frequency shifts have been measured as a function of distance from a saline tank. The CRC coil appears to have advantages with respect to tuning and matching. A high-resolution image of the rotator cuff is shown as an illustration of coil performance.

Entities:  

Mesh:

Year:  1986        PMID: 3747820     DOI: 10.1002/mrm.1910030412

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  8 in total

1.  Advances towards using finger/toenail dosimetry to triage a large population after potential exposure to ionizing radiation.

Authors:  Xiaoming He; Jiang Gui; Thomas P Matthews; Benjamin B Williams; Steven G Swarts; Oleg Grinberg; Jason Sidabras; Dean E Wilcox; Harold M Swartz
Journal:  Radiat Meas       Date:  2011-09       Impact factor: 1.898

2.  Applications of specialized coils for high-resolution MRI on a whole-body scanner.

Authors:  J Mäurer; H Requardt; B Sander; F D Knollmann; A J Lemke; T J Vogl; R Felix
Journal:  MAGMA       Date:  1996-03       Impact factor: 2.310

3.  A microwave resonator for limiting depth sensitivity for electron paramagnetic resonance spectroscopy of surfaces.

Authors:  Jason W Sidabras; Shiv K Varanasi; Richard R Mett; Steven G Swarts; Harold M Swartz; James S Hyde
Journal:  Rev Sci Instrum       Date:  2014-10       Impact factor: 1.523

4.  MRI surface-coil pair with strong inductive coupling.

Authors:  Richard R Mett; Jason W Sidabras; James S Hyde
Journal:  Rev Sci Instrum       Date:  2016-12       Impact factor: 1.523

5.  Improved homogeneity of the transmit field by simultaneous transmission with phased array and volume coil.

Authors:  Nikolai I Avdievich; Sukhoon Oh; Hoby P Hetherington; Christopher M Collins
Journal:  J Magn Reson Imaging       Date:  2010-08       Impact factor: 4.813

6.  Development of an inductively coupled MR coil system for imaging and spectroscopic analysis of an implantable bioartificial construct at 11.1 T.

Authors:  Nelly A Volland; Thomas H Mareci; Ioannis Constantinidis; Nicholas E Simpson
Journal:  Magn Reson Med       Date:  2010-04       Impact factor: 4.668

7.  Autobiography of James S. Hyde.

Authors:  James S Hyde
Journal:  Appl Magn Reson       Date:  2017-10-27       Impact factor: 0.831

8.  A comparison of Lenz lenses and LC resonators for NMR signal enhancement.

Authors:  Mazin Jouda; Robert Kamberger; Jochen Leupold; Nils Spengler; Jürgen Hennig; Oliver Gruschke; Jan G Korvink
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2017-11-21       Impact factor: 1.176

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.