Literature DB >> 8773999

Applications of specialized coils for high-resolution MRI on a whole-body scanner.

J Mäurer1, H Requardt, B Sander, F D Knollmann, A J Lemke, T J Vogl, R Felix.   

Abstract

To investigate the application of a mini-coil surface system for high-resolution MRI, 60 volunteers were examined in a 1.5-T whole-body scanner. Two replaceable probe heads were available: a circular 2.5-cm coil and a quadratic 5-cm coil, both of which were placed directly on the skin. The skin layers, Achilles tendon and finger joints were examined with the 2.5-cm coil and a FOV of 25 X 25 mm2. A matrix of 256 pixels resulted in a pixel size of 0.098 X 0.098 mm2. For imaging of the carpal tunnel, the 5-cm coil was used in transverse orientation. The FOV was 50 X 50 mm2 so that a matrix of 256 X 256 pixels led to a pixel size of 0.195 X 0.195 mm2. The resulting spatial resolution permitted visualization of the epidermis, dermis and subcutis, resulting in clear definition of anatomical detail of the musculoskeletal system. MRI measurement of skin-layer thickness did not correlate with histometric data (p < 0.05). This discrepancy was due in part to shrinkage of the tumor specimen on histologic preparation. Other causes include the motion artifacts and the limited accuracy of determining thickness on the MRI display unit.

Entities:  

Mesh:

Year:  1996        PMID: 8773999     DOI: 10.1007/bf01759777

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  25 in total

1.  The carpal-tunnel syndrome; a clinical and anatomical study.

Authors:  R C TANZER
Journal:  J Bone Joint Surg Am       Date:  1959-06       Impact factor: 5.284

2.  Simultaneous image acquisition from the head (or body) coil and a surface coil.

Authors:  J S Hyde; W Froncisz; A Jesmanowicz; J B Kneeland
Journal:  Magn Reson Med       Date:  1988-02       Impact factor: 4.668

3.  Surface coil for MR imaging of the skin.

Authors:  J S Hyde; A Jesmanowicz; J B Kneeland
Journal:  Magn Reson Med       Date:  1987-11       Impact factor: 4.668

4.  Thickness, cross-sectional areas and depth of invasion in the prognosis of cutaneous melanoma.

Authors:  A Breslow
Journal:  Ann Surg       Date:  1970-11       Impact factor: 12.969

5.  MR imaging of the carpal tunnel: normal anatomy and preliminary findings in the carpal tunnel syndrome.

Authors:  W D Middleton; J B Kneeland; G M Kellman; J D Cates; J R Sanger; A Jesmanowicz; W Froncisz; J S Hyde
Journal:  AJR Am J Roentgenol       Date:  1987-02       Impact factor: 3.959

6.  [Clinico-anatomic studies of the carpal tunnel of the human hand].

Authors:  H M Schmidt; T Moser; D Lucas
Journal:  Handchir Mikrochir Plast Chir       Date:  1987-05       Impact factor: 1.018

7.  Magnetic resonance in dermatology.

Authors:  A Zemtsov; L Dixon
Journal:  Arch Dermatol       Date:  1993-02

8.  High-resolution magnetic resonance in clinical image system.

Authors:  J Mäurer; H Requardt; F H Müller; J C Böck; R Felix
Journal:  Lancet       Date:  1993-07-31       Impact factor: 79.321

9.  MR imaging using specialized coils.

Authors:  M R Fisher; B Barker; E G Amparo; G Brandt; M Brant-Zawadzki; H Hricak; C B Higgins
Journal:  Radiology       Date:  1985-11       Impact factor: 11.105

10.  Diagnostic utility of magnetic resonance imaging in malignant melanoma.

Authors:  M Takahashi; H Kohda
Journal:  J Am Acad Dermatol       Date:  1992-07       Impact factor: 11.527

View more
  1 in total

1.  In vivo high-resolution magnetic resonance skin imaging at 1.5 T and 3 T.

Authors:  Joëlle K Barral; Neal K Bangerter; Bob S Hu; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2010-03       Impact factor: 4.668

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.