Literature DB >> 25362434

A microwave resonator for limiting depth sensitivity for electron paramagnetic resonance spectroscopy of surfaces.

Jason W Sidabras1, Shiv K Varanasi1, Richard R Mett1, Steven G Swarts2, Harold M Swartz3, James S Hyde1.   

Abstract

A microwave Surface Resonator Array (SRA) structure is described for use in Electron Paramagnetic Resonance (EPR) spectroscopy. The SRA has a series of anti-parallel transmission line modes that provides a region of sensitivity equal to the cross-sectional area times its depth sensitivity, which is approximately half the distance between the transmission line centers. It is shown that the quarter-wave twin-lead transmission line can be a useful element for design of microwave resonators at frequencies as high as 10 GHz. The SRA geometry is presented as a novel resonator for use in surface spectroscopy where the region of interest is either surrounded by lossy material, or the spectroscopist wishes to minimize signal from surrounding materials. One such application is in vivo spectroscopy of human finger-nails at X-band (9.5 GHz) to measure ionizing radiation dosages. In order to reduce losses associated with tissues beneath the nail that yield no EPR signal, the SRA structure is designed to limit depth sensitivity to the thickness of the fingernail. Another application, due to the resonator geometry and limited depth penetration, is surface spectroscopy in coating or material science. To test this application, a spectrum of 1.44 μM of Mg(2+) doped polystyrene 1.1 mm thick on an aluminum surface is obtained. Modeling, design, and simulations were performed using Wolfram Mathematica (Champaign, IL; v. 9.0) and Ansys High Frequency Structure Simulator (HFSS; Canonsburg, PA; v. 15.0). A micro-strip coupling circuit is designed to suppress unwanted modes and provide a balanced impedance transformation to a 50 Ω coaxial input. Agreement between simulated and experimental results is shown.

Entities:  

Mesh:

Year:  2014        PMID: 25362434      PMCID: PMC4201662          DOI: 10.1063/1.4898179

Source DB:  PubMed          Journal:  Rev Sci Instrum        ISSN: 0034-6748            Impact factor:   1.523


  13 in total

Review 1.  In vivo EPR dosimetry to quantify exposures to clinically significant doses of ionising radiation.

Authors:  Harold M Swartz; Akinori Iwasaki; Tadeusz Walczak; Eugene Demidenko; Ildar Salikhov; Nadeem Khan; Piotr Lesniewski; Jerry Thomas; Alex Romanyukha; David Schauer; Piotr Starewicz
Journal:  Radiat Prot Dosimetry       Date:  2006-04-27       Impact factor: 0.972

2.  EPR dosimetry in chemically treated fingernails.

Authors:  A Romanyukha; F Trompier; B Leblanc; C Calas; I Clairand; C A Mitchell; James G Smirniotopoulos; H M Swartz
Journal:  Radiat Meas       Date:  2007-08       Impact factor: 1.898

3.  Electron paramagnetic resonance in human fingernails: the sponge model implication.

Authors:  R A Reyes; A Romanyukha; F Trompier; C A Mitchell; I Clairand; T De; L A Benevides; H M Swartz
Journal:  Radiat Environ Biophys       Date:  2008-06-27       Impact factor: 1.925

4.  Biological dosimetry by the triage dicentric chromosome assay: potential implications for treatment of acute radiation syndrome in radiological mass casualties.

Authors:  Horst Romm; Ruth C Wilkins; C Norman Coleman; Patricia K Lillis-Hearne; Terry C Pellmar; Gordon K Livingston; Akio A Awa; Mark S Jenkins; Mitsuaki A Yoshida; Ursula Oestreicher; Pataje G S Prasanna
Journal:  Radiat Res       Date:  2011-01-04       Impact factor: 2.841

5.  In vivo MR microscopy of the human skin.

Authors:  H K Song; F W Wehrli; J Ma
Journal:  Magn Reson Med       Date:  1997-02       Impact factor: 4.668

6.  Use of polyacrylamide as a tissue-equivalent material in the microwave range.

Authors:  D Andreuccetti; M Bini; A Ignesti; R Olmi; N Rubino; R Vanni
Journal:  IEEE Trans Biomed Eng       Date:  1988-04       Impact factor: 4.538

7.  Sulphur radicals formed by cutting alpha-keratin.

Authors:  H Chandra; M C Symons
Journal:  Nature       Date:  1987 Aug 27-Sep 2       Impact factor: 49.962

8.  Surface coil for MR imaging of the skin.

Authors:  J S Hyde; A Jesmanowicz; J B Kneeland
Journal:  Magn Reson Med       Date:  1987-11       Impact factor: 4.668

9.  Coupling of Waveguide and Resonator by Inductive and Capacitive Irises for EPR Spectroscopy.

Authors:  R R Mett; J W Sidabras; J S Hyde
Journal:  Appl Magn Reson       Date:  2009       Impact factor: 0.831

10.  Electron paramagnetic resonance dosimetry for a large-scale radiation incident.

Authors:  Harold M Swartz; Ann Barry Flood; Benjamin B Williams; Ruhong Dong; Steven G Swarts; Xiaoming He; Oleg Grinberg; Jason Sidabras; Eugene Demidenko; Jiang Gui; David J Gladstone; Lesley A Jarvis; Maciej M Kmiec; Kyo Kobayashi; Piotr N Lesniewski; Stephen D P Marsh; Thomas P Matthews; Roberto J Nicolalde; Patrick M Pennington; Timothy Raynolds; Ildar Salikhov; Dean E Wilcox; Bassem I Zaki
Journal:  Health Phys       Date:  2012-09       Impact factor: 1.316

View more
  6 in total

1.  Dielectric-Backed Aperture Resonators for X-Band in vivo EPR Nail Dosimetry.

Authors:  Oleg Grinberg; Jason W Sidabras; Dmitriy S Tipikin; Vladimir Krymov; Michael Mariani; Matthew M Feldman; Maciej M Kmiec; Sergey V Petryakov; Spencer Brugger; Brandon Carr; Wilson Schreiber; Steven G Swarts; Harold M Swartz
Journal:  Radiat Prot Dosimetry       Date:  2016-07-13       Impact factor: 0.972

Review 2.  Using Stable Free Radicals to Obtain Unique and Clinically Useful Data In Vivo in Human Subjects.

Authors:  Harold M Swartz
Journal:  Radiat Prot Dosimetry       Date:  2016-11-24       Impact factor: 0.972

3.  Developments in Biodosimetry Methods for Triage With a Focus on X-band Electron Paramagnetic Resonance In Vivo Fingernail Dosimetry.

Authors:  Steven G Swarts; Jason W Sidabras; Oleg Grinberg; Dmitriy S Tipikin; Maciej M Kmiec; Sergey V Petryakov; Wilson Schreiber; Victoria A Wood; Benjamin B Williams; Ann Barry Flood; Harold M Swartz
Journal:  Health Phys       Date:  2018-07       Impact factor: 1.316

4.  Autobiography of James S. Hyde.

Authors:  James S Hyde
Journal:  Appl Magn Reson       Date:  2017-10-27       Impact factor: 0.831

5.  On the Possibility of Miniature Diamond-Based Magnetometers Using Waveguide Geometries.

Authors:  Lykourgos Bougas; Alexander Wilzewski; Yannick Dumeige; Dionysios Antypas; Teng Wu; Arne Wickenbrock; Emilie Bourgeois; Milos Nesladek; Hannah Clevenson; Danielle Braje; Dirk Englund; Dmitry Budker
Journal:  Micromachines (Basel)       Date:  2018-06-01       Impact factor: 2.891

Review 6.  Scientific and Logistical Considerations When Screening for Radiation Risks by Using Biodosimetry Based on Biological Effects of Radiation Rather than Dose: The Need for Prior Measurements of Homogeneity and Distribution of Dose.

Authors:  Harold M Swartz; Ann Barry Flood; Vijay K Singh; Steven G Swarts
Journal:  Health Phys       Date:  2020-07       Impact factor: 2.922

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.