In vitro hemodynamic characteristics of tissue bioprostheses in the aortic position.

A P Yoganathan, Y R Woo, H W Sung, F P Williams, R H Franch, M Jones.   

Abstract

The in vitro hemodynamic characteristics of a variety of old and new generation porcine and bovine pericardial bioprostheses were investigated in the aortic position under pulsatile flow conditions. The following valves were studied: Carpentier-Edwards porcine (Models 2625 and 2650), Carpentier-Edwards pericardial, Hancock porcine (Models 242, 250, and 410), Hancock pericardial, and Ionescu-Shiley (standard and low-profile) bioprostheses. The pressure drop results indicated that the old design valves had performance indices in the range of 0.30 to 0.42, whereas the new low-pressure fixed designs have performance indices of 0.50 to 0.70. Flow visualization and velocity and turbulent shear stress measurements, conducted with a two-dimensional laser Doppler anemometer system, indicated that all tissue valve designs created jet-type flow fields. The intensity of the jets and turbulence levels were less severe with the new designs. The old designs created higher peak jet velocities and higher levels of turbulent shear stresses. On the whole, pericardial bioprostheses have better in vitro hemodynamic characteristics than porcine bioprostheses. These observations should have applications regarding the clinical choice of bioprosthetic valves and have implications regarding further improvements in the preparation and design of bioprosthetic valves.

Entities:  

Mesh:

Year:  1986        PMID: 3736078

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  4 in total

1.  Assessment of prosthetic aortic valve performance by magnetic resonance velocity imaging.

Authors:  R Botnar; E Nagel; M B Scheidegger; E M Pedersen; O Hess; P Boesiger
Journal:  MAGMA       Date:  2000-02       Impact factor: 2.310

2.  Ionescu-Shiley bovine pericardial bioprostheses. Histologic and ultrastructural studies.

Authors:  S L Hilbert; V J Ferrans; H A McAllister; D A Cooley
Journal:  Am J Pathol       Date:  1992-05       Impact factor: 4.307

3.  Effect of Arched Leaflets and Stent Profile on the Hemodynamics of Tri-Leaflet Flexible Polymeric Heart Valves.

Authors:  Atieh Yousefi; David L Bark; Lakshmi P Dasi
Journal:  Ann Biomed Eng       Date:  2016-06-15       Impact factor: 3.934

4.  Impact of patient-specific morphologies on sinus flow stasis in transcatheter aortic valve replacement: An in vitro study.

Authors:  Hoda Hatoum; Jennifer Dollery; Scott M Lilly; Juan Crestanello; Lakshmi Prasad Dasi
Journal:  J Thorac Cardiovasc Surg       Date:  2018-06-07       Impact factor: 5.209

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.