Literature DB >> 3733803

Loosening of the femoral component after total hip replacement. The thin black line and the sinking hip.

M Paterson, P Fulford, R Denham.   

Abstract

Review of the radiographs of 882 consecutive metal-to-polyethylene hip replacements after a mean follow-up of 6.8 years showed 72 cases (8%) of aseptic femoral loosening, all of which showed a lucent zone or black line between metal and cement. In 97% of the series this appeared within two years of the arthroplasty. Progress of loosening was unpredictable and only 24% had significant symptoms. Improved technique with methylmethacrylate cement in Stanmore prostheses had reduced loosening after two years from 7.9% to 0.4%. Methods of detection of early loosening are discussed.

Entities:  

Mesh:

Year:  1986        PMID: 3733803

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  10 in total

1.  A scoring system to determine radiological loosening in cemented total hip arthroplasty.

Authors:  D M Dall; I D Learmonth; M Solomon
Journal:  Int Orthop       Date:  1992       Impact factor: 3.075

2.  J. Wilson-MacDonald and E. Morscher: Comparison between straight- and curved-stem Müller femoral prostheses. 5- to 10-year results of 545 total hip replacements.

Authors:  B Mjöberg
Journal:  Arch Orthop Trauma Surg       Date:  1991       Impact factor: 3.067

3.  Femoral component fixation with and without intramedullary plug. A 6-year follow-up.

Authors:  S Suominen; I Antti-Poika; K Tallroth; S Santavirta; P Voutilainen; T S Lindholm
Journal:  Arch Orthop Trauma Surg       Date:  1996       Impact factor: 3.067

4.  Does femoral component loosening predispose to femoral fracture?: an in vitro comparison of cemented hips.

Authors:  Barton Harris; John R Owen; Jennifer S Wayne; William A Jiranek
Journal:  Clin Orthop Relat Res       Date:  2009-08-11       Impact factor: 4.176

5.  Interleukin 1 alpha and beta production by cells isolated from membranes around aseptically loose total joint replacements.

Authors:  C I Westacott; G Taylor; R Atkins; C Elson
Journal:  Ann Rheum Dis       Date:  1992-05       Impact factor: 19.103

6.  Effects of titanium particle size on osteoblast functions in vitro and in vivo.

Authors:  Moon G Choi; Hae S Koh; Daniel Kluess; Daniel O'Connor; Anshu Mathur; George A Truskey; Janet Rubin; David X F Zhou; K-L Paul Sung
Journal:  Proc Natl Acad Sci U S A       Date:  2005-03-08       Impact factor: 11.205

7.  Patient characteristics differently affect early cup and stem loosening in THA: a case-control study on 7,535 patients.

Authors:  C Röder; S Eggli; P Münger; M Melloh; A Busato
Journal:  Int Orthop       Date:  2007-02-15       Impact factor: 3.075

Review 8.  Periprosthetic fractures around the femoral stem: overcoming challenges and avoiding pitfalls.

Authors:  Andrew N Fleischman; Antonia F Chen
Journal:  Ann Transl Med       Date:  2015-09

9.  Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs.

Authors:  Gholam Hossein Shahgheraghi; Frcs C Seyed Ali Hashemi
Journal:  Iran J Med Sci       Date:  2015-09

10.  Correlation between the bone mineral density and stress on femur around a Duetto SI stem.

Authors:  Rina Sakai; Takeaki Yamamoto; Katsufumi Uchiyama; Kentaro Uchida; Masaki Nakao; Kiyoshi Mabuchi
Journal:  ScientificWorldJournal       Date:  2014-06-26
  10 in total