Single cuff comparison of two methods for indirect measurement of arterial blood pressure: standard auscultatory method versus automatic oscillometric method.

H Pessenhofer.   

Abstract

With the introduction of automatic oscillometric systems for indirect measurement of arterial blood pressure (e.g. DINAMAP), the problem of correspondence between that method and the standard auscultatory method arose. For an exact and valid comparison of two methods, for physiological and methodological reasons, both measurements have to be performed simultaneously and using only one single cuff. Applying a methodological approach fulfilling these preconditions and offering in addition the advantage of a graphic documentation of the individual measurement cycles, we were able to investigate both methods in a sample of 216 comparative experiments. We found a mean difference (auscultatory method minus oscillometric method) between the methods (bias) of -0.82 mm Hg (-0.109 kPa) for systolic pressure, 1.25 mm Hg (0.166 kPa) for diastolic pressure and 1.00 mm Hg (0.133 kPa) for mean pressure. Except for systolic pressure, the differences were statistically significant (paired t-test and analysis of variance). We also obtained a significant negative correlation between the differences and the average of both pressure values (decreasing error with increasing pressure) and a significant negative correlation between differences and heart rate (decreasing differences with increasing heart rate). The conclusions drawn from the comparative study are that, although the oscillometric method exhibited a tendency to higher systolic and lower diastolic measurement values compared to the auscultatory method, both methods are well comparable and the differences are below the level of physiological and clinical significance.

Mesh:

Year:  1986        PMID: 3718426     DOI: 10.1007/bf01907432

Source DB:  PubMed          Journal:  Basic Res Cardiol        ISSN: 0300-8428            Impact factor:   17.165


  9 in total

1.  [Studies on the theory of auscultatory blood pressure measurement].

Authors:  T KENNER; O H GAUER
Journal:  Pflugers Arch Gesamte Physiol Menschen Tiere       Date:  1962

2.  Pulse wave reflection at the collapsed segment of an artery in Riva-Rocci's method.

Authors:  T Kenner
Journal:  Pflugers Arch       Date:  1976-08-24       Impact factor: 3.657

3.  Indirect measurement of mean blood pressure in the anesthetized patient.

Authors:  M Yelderman; A K Ream
Journal:  Anesthesiology       Date:  1979-03       Impact factor: 7.892

4.  Criteria for evaluation of automated blood pressure measuring devices for use in hypertensive screening programs. A report of the Committee on Criteria and Methods of the Council on Epidemiology, American Heart Association.

Authors:  M Feinleib; D Labarthe; R Shekelle; L Kuller
Journal:  Circulation       Date:  1974-03       Impact factor: 29.690

5.  Noninvasive automatic determination of mean arterial pressure.

Authors:  M Ramsey
Journal:  Med Biol Eng Comput       Date:  1979-01       Impact factor: 2.602

6.  Comparison of exercise blood pressure measured by technician and an automated system.

Authors:  J A Garcia-Gregory; A S Jackson; J Studeville; W G Squires; C A Owen
Journal:  Clin Cardiol       Date:  1984-05       Impact factor: 2.882

7.  [Semi-automatic measurement of blood pressure--how reliable is it? (author's transl)].

Authors:  R A Steiner; T F Lüscher; W Siegenthaler; W Vetter
Journal:  Dtsch Med Wochenschr       Date:  1980-12-26       Impact factor: 0.628

8.  The meaning of the point of maximum oscillations in cuff pressure in the indirect measurement of blood pressure--part ii.

Authors:  G W Mauck; C R Smith; L A Geddes; J D Bourland
Journal:  J Biomech Eng       Date:  1980-02       Impact factor: 2.097

9.  [Are automatic devices suitable for blood pressure determinations?].

Authors:  C Adorjani; W Siegenthaler; W Vetter
Journal:  Schweiz Med Wochenschr       Date:  1979-09-01
  9 in total
  4 in total

Review 1.  Can blood pressure be measured during exercise? A review.

Authors:  J T Lightfoot
Journal:  Sports Med       Date:  1991-11       Impact factor: 11.136

2.  Blood pressure monitoring: automated oscillometric devices.

Authors:  M Ramsey
Journal:  J Clin Monit       Date:  1991-01

Review 3.  Arterial blood pressure and its measurement.

Authors:  T Kenner
Journal:  Basic Res Cardiol       Date:  1988 Mar-Apr       Impact factor: 17.165

4.  Automatic oscillometric NIBP (noninvasive automatic blood pressure machines) versus manual auscultatory blood pressure in the PACU.

Authors:  M Ramsey
Journal:  J Clin Monit       Date:  1994-03
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.