Pulse wave reflection at the collapsed segment of an artery in Riva-Rocci's method.

T Kenner.   

Abstract

The contours of pressure and flow of a pulse wave arriving at the entrance of a collapsed segment of an elastic tube can be described by application of the basic laws of reflection. The collapsed segment acts like a valve. It is opened by the pressure of the pulse wave when the pressure within the tube becomes higher than the "collapse pressure", i.e. the pressure exerted on the segment from outside. This opening of the collapsed segment suddenly changes the sign of the pulse wave reflection from positive to negative; thus a typical contour change of the pulse proximal to the segment is observed. The most obvious effect is a reduction of the pulse pressure. The extent of this reduction is a function of the collapse pressure. A typical example of this phenomenon can be observed in an artery proximal to the segment which is collapsed due to pressure exerted by an inflated Riva-Rocci cuff. The effect is explained by the assumption that the sign of reflection changes when the pressure of the pulse wave crosses the level of the cuff pressure. This explanation is supported by the results of model experiments.

Mesh:

Year:  1976        PMID: 986636     DOI: 10.1007/bf00581766

Source DB:  PubMed          Journal:  Pflugers Arch        ISSN: 0031-6768            Impact factor:   3.657


  3 in total

1.  [Studies on the theory of auscultatory blood pressure measurement].

Authors:  T KENNER; O H GAUER
Journal:  Pflugers Arch Gesamte Physiol Menschen Tiere       Date:  1962

2.  A computer simulation of arterial dynamics in the human leg.

Authors:  J K Raines; M Y Jaffrin; A H Shapiro
Journal:  J Biomech       Date:  1974-01       Impact factor: 2.712

3.  Pressure-flow characteristics of collapsible tubes: a reconciliation of seemingly contradictory results.

Authors:  R W Brower; A Noordergraaf
Journal:  Ann Biomed Eng       Date:  1973-03       Impact factor: 3.934

  3 in total
  2 in total

Review 1.  Arterial blood pressure and its measurement.

Authors:  T Kenner
Journal:  Basic Res Cardiol       Date:  1988 Mar-Apr       Impact factor: 17.165

2.  Single cuff comparison of two methods for indirect measurement of arterial blood pressure: standard auscultatory method versus automatic oscillometric method.

Authors:  H Pessenhofer
Journal:  Basic Res Cardiol       Date:  1986 Jan-Feb       Impact factor: 17.165