Literature DB >> 3716011

[Mechanical principle of external fixation for dorsal stabilization of thoracic and lumbar vertebrae].

P Kluger, H J Gerner.   

Abstract

The mechanical principle of function of the Harrington instruments or of the spinal stabilization by means of plates does not meet the anatomical and mechanical conditions in instable fractures of the thoracic and lumbar spine sufficiently. The requested qualities in regard to fixation of the material, shortness of fusion distance, possibility of reduction and variability according to individual situations can be met only by the fixateur externe. Magerl was able to verify the correctness of this thesis by means of the fixateur externe constructed by himself. It was logic for us to practice the mechanical principle of the fixateur externe in using the implantation instruments which were positioned directly to the spine. The first instruments of this kind were introduced by Dick in 1983 and were used in Bad Wildungen since November 1983 successfully. The practical experiences of more than 40 operations using the Dick fixateur interne resulted in the development of own instruments applied by us since the beginning of 1985 as preliminary prototypes.

Entities:  

Mesh:

Year:  1986        PMID: 3716011     DOI: 10.1007/bf02588325

Source DB:  PubMed          Journal:  Unfallchirurgie        ISSN: 0340-2649


  9 in total

Review 1.  Spinal injuries with tetraplegia and paraplegia.

Authors:  G M Bedbrook
Journal:  J Bone Joint Surg Br       Date:  1979-08

2.  [Anatomical study of the vertebral pedicles. Surgical application].

Authors:  G Saillant
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  1976-03

3.  Osteosynthesis of thoraco-lumbar spine fractures with metal plates screwed through the vertebral pedicles.

Authors:  R Roy-Camille; G Saillant; D Berteaux; V Salgado
Journal:  Reconstr Surg Traumatol       Date:  1976

4.  [A new target principle for the axial alignment in the direction of roentgen rays].

Authors:  P Kluger
Journal:  Chirurg       Date:  1983-06       Impact factor: 0.955

5.  [Indication and technique of operative treatment of traumatic paraplegia (author's transl)].

Authors:  U Bötel
Journal:  Unfallheilkunde       Date:  1982-02

6.  [Early surgical therapy of traumatic injuries of the spinal cord (author's transl)].

Authors:  F Magerl
Journal:  Orthopade       Date:  1980-01       Impact factor: 1.087

7.  [Operative fusion of the vertebral column].

Authors:  G Muhr; H Tscherne
Journal:  Unfallheilkunde       Date:  1982-07

8.  Thoracolumbar spinal injuries. A comparative study of recumbent and operative treatment in 100 patients.

Authors:  R R Jacobs; M A Asher; R K Snider
Journal:  Spine (Phila Pa 1976)       Date:  1980 Sep-Oct       Impact factor: 3.468

9.  A new device for internal fixation of thoracolumbar and lumbar spine fractures: the 'fixateur interne'.

Authors:  W Dick; P Kluger; F Magerl; O Woersdörfer; G Zäch
Journal:  Paraplegia       Date:  1985-08
  9 in total
  11 in total

1.  The fixateur interne for stabilising fractures of the thoracolumbar and lumbar spine.

Authors:  E Sim; P M Stergar
Journal:  Int Orthop       Date:  1992       Impact factor: 3.075

2.  Management of thoraco-lumbar fractures.

Authors:  M L Babu; M A Wani
Journal:  Acta Neurochir (Wien)       Date:  1990       Impact factor: 2.216

3.  [Cross stabilization of the internal fixator of the spine].

Authors:  O Wörsdörfer; M Arand; L Claes
Journal:  Unfallchirurgie       Date:  1988-02

4.  Fixation of thoracolumbar fractures with the Dick fixator: the influence of transpedicular bone grafting.

Authors:  R J Crawford; G N Askin
Journal:  Eur Spine J       Date:  1994       Impact factor: 3.134

5.  Comparative study of different dorsal stabilization techniques in recent thoraco-lumbar spine fractures.

Authors:  P Eysel; G Meinig
Journal:  Acta Neurochir (Wien)       Date:  1991       Impact factor: 2.216

6.  [Treatment of unstable thoracic and lumbar spinal fractures with Cotrel-Dubousset instruments].

Authors:  P A Ostermann; R T Holt; J R Johnson; S L Henry
Journal:  Langenbecks Arch Chir       Date:  1990

7.  Results of lumbosacral distraction spondylodesis for the treatment of spondylolisthesis, failed-back syndrome, and lumbar instability.

Authors:  J Möller; R H Wittenberg; L P Nolte; M Jergas; R Willburger; J Krämer
Journal:  Eur Spine J       Date:  1992-09       Impact factor: 3.134

8.  [History of the treatment of paralyzed patients in West Germany].

Authors:  F W Meinecke
Journal:  Unfallchirurgie       Date:  1988-04

9.  [History of internal fixators. The subsequent importance for spinal surgery].

Authors:  W Dick; M Rickert
Journal:  Unfallchirurg       Date:  2015-12       Impact factor: 1.000

10.  [Comparative study of various dorsal stabilization procedures in recent fractures of the thoracic spine].

Authors:  P Eysel; G Meinig; F Sanner
Journal:  Unfallchirurgie       Date:  1991-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.