Literature DB >> 3657401

Operational safety issues in MRI.

R E Gangarosa1, J E Minnis, J Nobbe, D Praschan, R W Genberg.   

Abstract

The clinical usefulness of a diagnostic modality is weighed by considering its potential diagnostic benefit against its potential risk for a patient in question. Magnetic resonance imagining appears to offer both high efficacy and safety under most circumstances. Our understanding of the conditions under which MRI is safe and effective has undergone continual refinement with technological advances and clinical experience. The early emphasis on safety issues of MR focussed on consideration of bioeffects of RF and magnetic fields. More recently, hundreds of operating clinical MR sites, performing hundreds of thousands of clinical examinations to date, have provided a greater awareness of operational safety issues. Much of this experience is summarized in device labeling provided by manufacturers of MR devices, summaries prepared by regulatory agencies, and case reports in the medical literature. The purpose of this article is to review a broad range of safety considerations involved in the operation of MR imagers. The discussion is in two parts: (1) a short update of reported incidents and (2) an analysis of safety issues.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3657401     DOI: 10.1016/0730-725x(87)90006-3

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  4 in total

1.  MR imaging-related heating of deep brain stimulation electrodes: in vitro study.

Authors:  Daniel A Finelli; Ali R Rezai; Paul M Ruggieri; Jean A Tkach; John A Nyenhuis; Greg Hrdlicka; Ashwini Sharan; Jorge Gonzalez-Martinez; Paul H Stypulkowski; Frank G Shellock
Journal:  AJNR Am J Neuroradiol       Date:  2002 Nov-Dec       Impact factor: 3.825

2.  In situ active control of noise in a 4 T MRI scanner.

Authors:  Mingfeng Li; Brent Rudd; Teik C Lim; Jing-Huei Lee
Journal:  J Magn Reson Imaging       Date:  2011-07-12       Impact factor: 4.813

3.  Simulation study on active noise control for a 4-T MRI scanner.

Authors:  Mingfeng Li; Teik C Lim; Jing-Huei Lee
Journal:  Magn Reson Imaging       Date:  2007-12-03       Impact factor: 2.546

4.  Data on the safety of repeated MRI in healthy children.

Authors:  Scott K Holland; Mekibib Altaye; Sara Robertson; Anna W Byars; Elena Plante; Jerzy P Szaflarski
Journal:  Neuroimage Clin       Date:  2014-02-09       Impact factor: 4.881

  4 in total