Influence of sampling site and flow area on cardiac output measurements by Doppler echocardiography.

H Dittmann1, W Voelker, K R Karsch, L Seipel.   

Abstract

In 40 patients cardiac output was simultaneously determined by pulsed Doppler echocardiography and thermodilution (range 4.0 to 10.2 liters/min). The sample volume was located in the center of the mitral anulus, at the tips of the mitral leaflets and in the center of the aortic anulus. Circular cross-sectional areas of the mitral anulus, aortic anulus and aortic bulbus were calculated from M-mode and two-dimensional echocardiographic diameters. The varying short axis of the elliptical mitral opening area was obtained from the diastolic leaflet separation in the M-mode, and the long axis was derived from the maximal mitral orifice area or mitral anulus diameter. Cardiac output was calculated by multiplying time-velocity integrals with the different areas and heart rate. Doppler flow measurements correlated significantly with the thermodilution method (r = 0.79 to 0.93). Flow measurements at the aortic anulus were most accurate (r = 0.93, SEE = 0.589 liter/min) if the annular area was derived from the M-mode tracing. Measurement of the anulus in the apical five chamber view yielded a significant underestimation and the area of the aortic bulbus provided an overestimation of cardiac output. Left ventricular inflow was underestimated at the mitral leaflet tips and overestimated at the mitral anulus. The accuracy of pulsed Doppler cardiac output measurements strongly depends on the assumed flow area and sampling site. Both should be determined at the same level in the inflow or outflow tract of the left ventricle. Measurement of cardiac output in the center of the aortic anulus provided the highest accuracy.

Entities:  

Mesh:

Year:  1987        PMID: 3655148     DOI: 10.1016/s0735-1097(87)80275-9

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  21 in total

1.  Unique variant of partial anomalous pulmonary venous connection with intact atrial septum.

Authors:  F A Fish; J Davies; T P Graham
Journal:  Pediatr Cardiol       Date:  1991-07       Impact factor: 1.655

2.  Multi-channel electrical bioimpedance: a new noninvasive method to simultaneously measure cardiac and peripheral blood flow.

Authors:  Alfred W H Stanley; Jeffery W Herald; Constantine L Athanasuleas; Saji C Jacob; Scott W Sims; Alfred A Bartolucci; Alexander N Tsoglin
Journal:  J Clin Monit Comput       Date:  2007-10-09       Impact factor: 2.502

3.  Determination of prestenotic flow volume using an automated method based on colour Doppler imaging for evaluating orifice area by the continuity equation: validation in a pulsatile flow model.

Authors:  K Dennig; H J Nesser; D Hall; H U Haase; A Schömig
Journal:  Heart       Date:  1998-04       Impact factor: 5.994

4.  Multi-channel electrical bioimpedance: a non-invasive method to simultaneously measure cardiac output and individual arterial limb flow in patients with cardiovascular disease.

Authors:  Alfred W H Stanley; Jeffery W Herald; Constantine L Athanasuleas; Saji C Jacob; Alfred A Bartolucci; Alexander N Tsoglin
Journal:  J Clin Monit Comput       Date:  2009-07-14       Impact factor: 2.502

5.  Cross sectional early mitral flow velocity profiles from colour Doppler.

Authors:  S O Samstad; H G Torp; D T Linker; O Rossvoll; T Skjaerpe; E Johansen; K Kristoffersen; B A Angelsen; L Hatle
Journal:  Br Heart J       Date:  1989-09

6.  Doppler measurement of cardiac output across prosthetic mitral valves.

Authors:  H Dittmann; W Voelker; K R Karsch; L Seipel
Journal:  Klin Wochenschr       Date:  1990-03-05

7.  Stroke volume and systolic time intervals: beat-to-beat comparison between echocardiography and ambulatory impedance cardiography in supine and tilted positions.

Authors:  G Cybulski; E Michalak; E Koźluk; A Piatkowska; W Niewiadomski
Journal:  Med Biol Eng Comput       Date:  2004-09       Impact factor: 2.602

8.  Changes in lung to finger circulation time measured via cardiopulmonary polygraphy in patients with varying types of heart disease.

Authors:  Tomoyuki Tobushi; Kazuya Hosokawa; Ko Abe; Satomi Kon-No; Toshiaki Kadokami; Ryo Nakamura; Hiroyuki Tsutsui; Shin-Ichi Ando
Journal:  Heart Vessels       Date:  2020-07-01       Impact factor: 2.037

9.  Transgastric, pulsed Doppler echocardiographic determination of cardiac output.

Authors:  A Descorps-Declere; N Smail; B Vigue; J Duranteau; O Mimoz; A Edouard; K Samii
Journal:  Intensive Care Med       Date:  1996-01       Impact factor: 17.440

10.  Diagnosis of central hypovolemia by using passive leg raising.

Authors:  Julien Maizel; Norair Airapetian; Emmanuel Lorne; Christophe Tribouilloy; Ziad Massy; Michel Slama
Journal:  Intensive Care Med       Date:  2007-05-17       Impact factor: 17.440

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.