Literature DB >> 3643928

Detection of intrinsically resistant (heteroresistant) Staphylococcus aureus with the Sceptor and AutoMicrobic systems.

S L Hansen, T J Walsh.   

Abstract

Modified procedures for the Sceptor Gram-Positive MIC Panel and the Vitek AutoMicrobic System GPS-M Card were evaluated for their ability to detect methicillin-resistant (heteroresistant) Staphylococcus aureus. A total of 398 clinical isolates (including 222 methicillin-resistant S. aureus) obtained from 10 hospitals were tested. Both systems had 2% NaCl in the oxacillin wells. Sceptor MIC panels were inoculated with an organism suspension prepared from an 18- to 24-h blood agar plate and were inoculated for a full 24 h at 35 degrees C before MICs were read. All methicillin-resistant S. aureus isolates were detected as resistant to oxacillin at greater than or equal to 8 micrograms/ml by the Sceptor method and at greater than 2 micrograms/ml by the Vitek method. All 176 oxacillin-susceptible, methicillin-susceptible S. aureus isolates were correctly distinguished from methicillin-resistant S. aureus isolates by Sceptor. However, with the Vitek system 29 methicillin-susceptible S. aureus isolates tested as falsely resistant to oxacillin and four isolates tested as falsely resistant to vancomycin. The modified testing procedure with the Sceptor system can be used reliably for accurate susceptibility testing of methicillin-resistant and methicillin-susceptible S. aureus. The Vitek GPS-M card does not accurately discriminate between methicillin-resistant and methicillin-susceptible S. aureus with an oxacillin breakpoint of greater than 2 micrograms/ml.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3643928      PMCID: PMC265910          DOI: 10.1128/jcm.25.2.412-415.1987

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  11 in total

1.  Evaluation of the newly modified AutoMicrobic system gram-positive susceptibility-MIC card for detection of methicillin-resistant Staphylococcus aureus.

Authors:  R T Lally; M N Ederer; B F Woolfrey
Journal:  J Clin Microbiol       Date:  1986-02       Impact factor: 5.948

2.  Methicillin-susceptible "methicillin-resistant Staphylococcus aureus": a sheep in wolves' clothing.

Authors:  J E Peacock
Journal:  Infect Control       Date:  1986-03

3.  Detection of oxacillin-resistant staphylococci by the AutoMicrobic system.

Authors:  R W Stotler; M C Meyer
Journal:  J Clin Microbiol       Date:  1983-11       Impact factor: 5.948

4.  New recommendations for disk diffusion antimicrobial susceptibility tests for methicillin-resistant (heteroresistant) staphylococci.

Authors:  L K McDougal; C Thornsberry
Journal:  J Clin Microbiol       Date:  1984-04       Impact factor: 5.948

5.  The role of beta-lactamase in staphylococcal resistance to penicillinase-resistant penicillins and cephalosporins.

Authors:  L K McDougal; C Thornsberry
Journal:  J Clin Microbiol       Date:  1986-05       Impact factor: 5.948

6.  Successful use of broth microdilution in susceptibility tests for methicillin-resistant (heteroresistant) staphylococci.

Authors:  C Thornsberry; L K McDougal
Journal:  J Clin Microbiol       Date:  1983-11       Impact factor: 5.948

7.  Methicillin-resistant Staphylococcus aureus: how reliable is laboratory reporting?

Authors:  D W Fleming; S D Helgerson; B L Mallery; L R Foster; M C White
Journal:  Infect Control       Date:  1986-03

8.  Detection of methicillin-resistant Staphylococcus aureus by microdilution and disk elution susceptibility systems.

Authors:  J M Boyce; L S Lytle; D A Walsh
Journal:  J Clin Microbiol       Date:  1984-12       Impact factor: 5.948

9.  Reevaluation of the ability of the standardized disk diffusion test to detect methicillin-resistant strains of Staphylococcus aureus.

Authors:  J M Boyce
Journal:  J Clin Microbiol       Date:  1984-06       Impact factor: 5.948

10.  Interlaboratory variation of antibiograms of methicillin-resistant and methicillin-susceptible Staphylococcus aureus strains with conventional and commercial testing systems.

Authors:  K E Aldridge; A Janney; C V Sanders; R L Marier
Journal:  J Clin Microbiol       Date:  1983-11       Impact factor: 5.948

View more
  7 in total

Review 1.  Expert systems in clinical microbiology.

Authors:  Trevor Winstanley; Patrice Courvalin
Journal:  Clin Microbiol Rev       Date:  2011-07       Impact factor: 26.132

2.  Rapid detection (4 h) of methicillin-resistant Staphylococcus aureus by a bioluminescence method.

Authors:  C H Park; D L Hixon; C M McLaughlin; J F Cook
Journal:  J Clin Microbiol       Date:  1988-06       Impact factor: 5.948

3.  Misclassification of susceptible strains of Staphylococcus aureus as methicillin-resistant S. aureus By a rapid automated susceptibility testing system.

Authors:  J Ribeiro; F D Vieira; T King; J B D'Arezzo; J M Boyce
Journal:  J Clin Microbiol       Date:  1999-05       Impact factor: 5.948

4.  Randomized double-blinded trial of rifampin with either novobiocin or trimethoprim-sulfamethoxazole against methicillin-resistant Staphylococcus aureus colonization: prevention of antimicrobial resistance and effect of host factors on outcome.

Authors:  T J Walsh; H C Standiford; A C Reboli; J F John; M E Mulligan; B S Ribner; J Z Montgomerie; M B Goetz; C G Mayhall; D Rimland
Journal:  Antimicrob Agents Chemother       Date:  1993-06       Impact factor: 5.191

5.  Multicenter laboratory evaluation of the bioMérieux Vitek antimicrobial susceptibility testing system with 11 antimicrobial agents versus members of the family Enterobacteriaceae and Pseudomonas aeruginosa.

Authors:  G V Doern; A B Brueggemann; R Perla; J Daly; D Halkias; R N Jones; M A Saubolle
Journal:  J Clin Microbiol       Date:  1997-08       Impact factor: 5.948

6.  Comparison of the Vitek Gram-Positive Susceptibility 106 card and the MRSA-screen latex agglutination test for determining oxacillin resistance in clinical bloodstream isolates of Staphylococcus aureus.

Authors:  T Yamazumi; S A Marshall; W W Wilke; D J Diekema; M A Pfaller; R N Jones
Journal:  J Clin Microbiol       Date:  2001-01       Impact factor: 5.948

7.  Evaluation of differential inoculum disk diffusion method and Vitek GPS-SA card for detection of oxacillin-resistant staphylococci.

Authors:  C C Knapp; M D Ludwig; J A Washington
Journal:  J Clin Microbiol       Date:  1994-02       Impact factor: 5.948

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.