| Literature DB >> 36250144 |
Emilia Wnuk1, Edyta Maj1, Anna Jabłońska-Pawlak2, Maria Jeczeń3, Katarzyna Rowińska-Berman1, Olgierd Rowiński1.
Abstract
Purpose: Although assessment of the orbital structures using magnetic resonance imaging (MRI) is well described in the literature, there is no consensus as to which measurement method is the most useful in exophthalmos assessment. The aim of the study was to correlate 2 MRI methods of exophthalmos measurement with exophthalmometry results and to determine a proper technique of exophthalmos measurement. Material and methods: Fifty-four patients (108 orbits) with exophthalmos in the course of Graves' orbitopathy were enrolled in the study. Two measurements on axial T2W orbital MRI images were performed by 2 independent radiologists: the distance from the interzygomatic line to the anterior surface of the globe (AD) and the distance from the interzygomatic line to the posterior sclera (PD). Within 4 weeks, an exophthalmometry was performed by an ophthalmologist using a Hertel exophthalmometer. The inter-observer variation was assessed using the Pearson correlation coefficient. Values were presented as mean and standard deviation, and the differences in values were explored with Student's t-test.Entities:
Keywords: Graves’ orbitopathy; Hertel exophthalmometry; MRI; exophthalmos; proptosis; thyroid-associated orbitopathy
Year: 2022 PMID: 36250144 PMCID: PMC9536203 DOI: 10.5114/pjr.2022.119939
Source DB: PubMed Journal: Pol J Radiol ISSN: 1733-134X
Detailed magnetic resonance imaging sequence parameters of the orbital imaging protocol
| Sequence | Plane | TR (ms) | TE (ms) | NEX | FOV (mm) |
|---|---|---|---|---|---|
| T2 | Axial | 4630 | 75 | 3.0 | 140 × 140 |
| T2 FS | Axial | 3770 | 75 | 3.0 | 140 × 140 |
| T2 FS | Coronal | 5030 | 75 | 2.0 | 144.4 × 160 |
| T2 | Coronal | 4500 | 75 | 2.0 | 144.4 × 160 |
| T1 | Axial | 573 | 16 | 2.0 | 160 × 160 |
| T1 | Coronal | 662 | 16 | 2.0 | 160 × 160 |
| T1 | Oblique sagittal of the left and right orbit | 518 | 16 | 2.0 | 160 × 160 |
FS – fat saturation, TR – time of repetition, TE – time of echo, NEX – number of excitations, FOV – field of view
Figure 1A). An axial T2-weighted sequence at the level of the lens and optic nerve. Techniques of proptosis measurement on imaging. Anterior distance (AD) between the interzygomatic line and the anterior surface of the globe. B) An axial T2-weighted sequence at the level of the lens and optic nerve. Techniques of proptosis measurement on imaging. Posterior distance (PD) from the interzygomatic line to the posterior sclera
Figure 2An axial T2-weighted sequence at the level of the lens and optic nerve. In severe exophthalmos, the globe is located anteriorly to the interzygomatic line, in which case the posterior distance values are below zero
Anterior and posterior distance measurements performed by 2 radiologists in magnetic resonance imaging (mm)
| Anterior distance | Posterior distance | ||||||
|---|---|---|---|---|---|---|---|
| Both eyes | Right eye | Left eye | Right eyes | Right eye | Left eye | ||
| First observer | Range | 14-29 | 14-28.3 | 15.2-29 | (–5.4)-9 | (–5.3)- 7.5 | (–5.4)-9 |
| Mean ± SD | 20.6 ± 3.1 | 20.6 ± 3.1 | 2.06 ± 0.31 | 2.9 ± 2.9 | 2.8 ± 2.9 | 3.1 ± 2.9 | |
| Median | 20.2 | 20.3 | 19.8 | 2.9 | 3.0 | 2.8 | |
| Second observer | Range | 14-28.4 | 14-28.4 | 15.1-27.9 | (–4.4)- 9.7 | (–4.4)- 9.2 | (–3.6)-9.7 |
| Mean ± SD | 20.7 ± 2.9 | 20.9 ± 2.9 | 20.5 ± 2.9 | 3.4 ± 2.8 | 3.2 ± 2.8 | 3.5 ± 2.9 | |
| Median | 20.2 | 20.6 | 20.1 | 3.7 | 3.6 | 3.7 | |
Hertel exophthalmometry results (mm)
| Both eyes | Right eye | Left eye | |
|---|---|---|---|
| Range | 15-30 | 16-29 | 15-30 |
| Mean ± SD | 21 ± 3.4 | 21.2 ± 3.2 | 20.9 ± 3.5 |
| Median | 21 | 21 | 21 |
Correlation between magnetic resonance imaging and exophthalmometry results
| First observer | Second observer | |||
|---|---|---|---|---|
| Right eye | Left eye | Right eye | Left eye | |
| Hertel exophthalmometry | 0.9 | 0.93 | 0.87 | 0.9 |