Literature DB >> 26186249

Proptosis--Correlation and Agreement between Hertel Exophthalmometry and Computed Tomography.

Norlina Ramli1, Shanmugam Kala1, Amir Samsudin1, Kartini Rahmat2, Zurina Zainal Abidin1.   

Abstract

AIM: To determine the correlation and agreement between Hertel exophthalmometry and computed tomography (CT) of the orbits in measuring proptosis.
MATERIALS AND METHODS: 80 patients (40 normal and 40 with proptosis) were recruited for this study. Exophthalmometry were performed on all of them using the Hertel exophthalmometer and CT. Values and correlations between the modalities were analysed with unpaired t-tests, intraclass correlation coefficients (ICC), and Pearson correlation coefficients (PCC). The Bland-Altman method was used to analyse the agreement between the two modalities.
RESULTS: Hertel exophthalmometer and CT measurements did not differ significantly (p > 0.05), although exophthalmometry measurements of the normal (14.5 ± 2.2 mm) and proptosis groups (20.5 ± 3.9 mm) were higher than those obtained from CT (13.9 ± 2.4 mm and 20.0 ± 3.7 mm, respectively). ICC for both the Hertel exophthalmometer and CT measurements were both 0.99, indicating high intra-observer reliability and reproducibility. PCC between Hertel exophthalmometer and CT measurements in both normal and proptosis groups were strongly correlated (r = 0.96 and 0.93, respectively, p = 0.01). The 95% limits of agreement (LOA) between Hertel exophthalmometer and CT measurements for the normal and proptosis groups were -0.70 to 1.78 mm and -2.36 to 3.33 mm, respectively.
CONCLUSION: Although Hertel exophthalmometer and CT measurements are similar and strongly correlated, they do not agree well with each other in the presence of proptosis. The measurements should not be used interchangeably as the differences between them may lead to errors in clinical interpretation.

Entities:  

Keywords:  Computed tomography; Hertel; exophthalmometer; orbit; proptosis

Mesh:

Year:  2015        PMID: 26186249     DOI: 10.3109/01676830.2015.1057291

Source DB:  PubMed          Journal:  Orbit        ISSN: 0167-6830


  11 in total

1.  Validation of Modified Hertel Exophthalmometer.

Authors:  Rizwana Fathima Jamal; Emmanuel Azariah; Deepak Pandyan; Ravindran Chinnaswami
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2020-09-11

2.  Cross-sectional computed tomography assessment of exophthalmos in comparison to clinical measurement via Hertel exophthalmometry.

Authors:  A Klingenstein; C Samel; A Garip-Kübler; C Hintschich; U G Müller-Lisse
Journal:  Sci Rep       Date:  2022-07-13       Impact factor: 4.996

3.  A Novel Three-Dimensional Vector Analysis of Axial Globe Position in Thyroid Eye Disease.

Authors:  Jie Guo; Jiang Qian; Yifei Yuan; Rui Zhang; Wenhu Huang
Journal:  J Ophthalmol       Date:  2017-04-09       Impact factor: 1.909

4.  Association of anthropometric markers with globe position: A population-based MRI study.

Authors:  Patrick Schmidt; Robert Kempin; Sönke Langner; Achim Beule; Stefan Kindler; Thomas Koppe; Henry Völzke; Till Ittermann; Clemens Jürgens; Frank Tost
Journal:  PLoS One       Date:  2019-02-07       Impact factor: 3.240

5.  Hertel exophthalmometer versus computed tomography scan in proptosis estimation in thyroid-associated orbitopathy.

Authors:  Na Ri Park; Jun Hyung Moon; Jeong Kyu Lee
Journal:  Clin Ophthalmol       Date:  2019-08-02

6.  Measurement of proptosis using computed tomography based three-dimensional reconstruction software in patients with Graves' orbitopathy.

Authors:  Jung Huh; Sang Joon Park; Jeong Kyu Lee
Journal:  Sci Rep       Date:  2020-09-03       Impact factor: 4.379

7.  Neural network-based method for diagnosis and severity assessment of Graves' orbitopathy using orbital computed tomography.

Authors:  Jaesung Lee; Wangduk Seo; Jaegyun Park; Won-Seon Lim; Ja Young Oh; Nam Ju Moon; Jeong Kyu Lee
Journal:  Sci Rep       Date:  2022-07-15       Impact factor: 4.996

8.  Computer-Assisted Secondary Orbital Reconstruction.

Authors:  Daman D Singh; Lara Schorn; E Bradley Strong; Michael Grant; Alexander Schramm; Karsten Hufendiek; Nils-Claudius Gellrich; Majeed Rana
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2020-07-09

9.  A Comparative Study of Clinical vs. Digital Exophthalmometry Measurement Methods.

Authors:  Tháıs de Sous Pereira; Cristina Hiromi Kuniyoshi; Cristiane de Almeida Leite; Eloisa M M S Gebrim; Mário L R Monteiro; Allan C Pieroni Gonçalves
Journal:  J Ophthalmol       Date:  2020-03-23       Impact factor: 1.909

10.  The feasibility analysis of calculating proptosis by simple Heron's formula.

Authors:  Weili Zhang; Qinying Huang; Yile Chen; Jinying Li
Journal:  PLoS One       Date:  2020-06-01       Impact factor: 3.752

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.