Literature DB >> 3238641

Effective pulmonary blood flow in normal children at rest.

J J Bowyer1, J O Warner, D M Denison.   

Abstract

Effective pulmonary blood flow was measured with a soluble inert gas uptake method (10% argon, 3.5% freon-22, 35% oxygen, balance nitrogen) in 98 apparently healthy children aged 5-14 years. None had any evidence of cardiorespiratory disease and all had normal values for absolute and dynamic lung volumes and transfer factor for carbon monoxide. Values of blood flow measured by a rebreathing method correlated reasonably closely with height, weight, body surface area, and lung volumes, and to a lesser extent with hand and foot size. The mean (SD) effective pulmonary blood flow index was 2.7 (0.31) 1 min-1 m-2. Small children found a single breath method of measuring flow more difficult to perform and the results were more variable.

Entities:  

Mesh:

Year:  1988        PMID: 3238641      PMCID: PMC461603          DOI: 10.1136/thx.43.12.972

Source DB:  PubMed          Journal:  Thorax        ISSN: 0040-6376            Impact factor:   9.139


  13 in total

1.  The measurement of pulmonary diffusing capacity for carbon monoxide by a rebreathing method.

Authors:  B M LEWIS; T H LIN; F E NOE; E J HAYFORD-WELSING
Journal:  J Clin Invest       Date:  1959-11       Impact factor: 14.808

2.  Cardiac output and related measurements and pressure values in the right heart and associated vessels, together with an analysis of the hemo-dynamic response to the inhalation of high oxygen mixtures in healthy subjects.

Authors:  B G BARRATT-BOYES; E H WOOD
Journal:  J Lab Clin Med       Date:  1958-01

3.  Changes in cardiac output with age.

Authors:  M BRANDFONBRENER; M LANDOWNE; N W SHOCK
Journal:  Circulation       Date:  1955-10       Impact factor: 29.690

4.  A standardized breath holding technique for the clinical measurement of the diffusing capacity of the lung for carbon monoxide.

Authors:  W S BLAKEMORE; R E FORSTER; J W MORTON; C M OGILVIE
Journal:  J Clin Invest       Date:  1957-01       Impact factor: 14.808

5.  Editorial: Progress report.

Authors:  J F Murray
Journal:  Am Rev Respir Dis       Date:  1975-01

6.  The measurement of effective pulmonary blood flow in the newborn infant using a mass spectrometer.

Authors:  E K Cotton
Journal:  Crit Care Med       Date:  1976 Sep-Oct       Impact factor: 7.598

7.  Determination of pulmonary blood flow by rebreathing of soluble inert gases.

Authors:  J Teichmann; F Adaro; A Veicsteinas; P Cerretelli; J Piiper
Journal:  Respiration       Date:  1974       Impact factor: 3.580

8.  Neonatal pulmonary ischemia. I. Clinical and physiological studies.

Authors:  J Chu; J A Clements; E K Cotton; M H Klaus; A Y Sweet; W H Tooley; B L Bradley; L C Brandorff
Journal:  Pediatrics       Date:  1967-10       Impact factor: 7.124

9.  Cardiac output by rebreathing in patients with cardiopulmonary diseases.

Authors:  M C Kallay; R W Hyde; R J Smith; R L Rothbard; B F Schreiner
Journal:  J Appl Physiol (1985)       Date:  1987-07

10.  Single-exhalation method for study of lobar and segmental lung function by mass spectrometry in man.

Authors:  D M Denison; N J Davies; M Meyer; R J Pierce; P Scheid
Journal:  Respir Physiol       Date:  1980-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.