Literature DB >> 3624031

CT-assisted assessment of bladder and rectum dose in gynecological implants.

C C Ling, M C Schell, K R Working, K Jentzsch, L Harisiadis, S Carabell, C C Rogers.   

Abstract

Eight patients who received gynecological implants with Fletcher-Suit type applicators were involved in this study. An orthogonal pair of films and computed tomographic scans were obtained for each patient. In the CT study, judicious use of contrast materials and selective window and level settings permitted clear delineation of the bladder and the rectum boundaries relative to the implanted applicators. In comparison to reference organ doses derived from the orthogonal film pair method, the maximum organ doses estimated from the CT-assisted evaluation were considerably higher, by approximately twofold on the average. The differences between the values estimated from the two methods vary from patient to patient, being highly dependent on the individual anatomy and the geometry of the implanted sources. These preliminary results point to the inaccuracy of the conventional method of estimating organ doses. CT-assisted evaluation may be necessary to accurately calculate organ doses in gynecological applications.

Entities:  

Mesh:

Year:  1987        PMID: 3624031     DOI: 10.1016/0360-3016(87)90327-0

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  15 in total

Review 1.  Radiation dose-volume effects of the urinary bladder.

Authors:  Akila N Viswanathan; Ellen D Yorke; Lawrence B Marks; Patricia J Eifel; William U Shipley
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-03-01       Impact factor: 7.038

2.  Preliminary study of correction of original metal artifacts due to 1-125 seeds in postimplant dosimetry for prostate permanent implant brachytherapy.

Authors:  Yutaka Takahashi; Shinichiro Mori; Takuyo Kozuka; Kotaro Gomi; Takayuki Nose; Takatoshi Tahara; Masahiko Oguchi; Takashi Yamashita
Journal:  Radiat Med       Date:  2006-02

3.  Localizing intracavitary brachytherapy applicators from cone-beam CT x-ray projections via a novel iterative forward projection matching algorithm.

Authors:  Damodar Pokhrel; Martin J Murphy; Dorin A Todor; Elisabeth Weiss; Jeffrey F Williamson
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

4.  Prostate cancer: contouring target and organs at risk by kilovoltage and megavoltage CT and MRI in patients with and without hip prostheses.

Authors:  Lorenzo Falcinelli; Isabella Palumbo; Valentina Radicchia; Fabio Arcidiacono; Valentina Lancellotta; Giampaolo Montesi; Fabio Matrone; Claudio Zucchetti; Marta Marcantonini; Vittorio Bini; Cynthia Aristei
Journal:  Br J Radiol       Date:  2015-10-14       Impact factor: 3.039

5.  Sigmoid dose using 3D imaging in cervical-cancer brachytherapy.

Authors:  Caroline L Holloway; Marie-Lynn Racine; Robert A Cormack; Desmond A O'Farrell; Akila N Viswanathan
Journal:  Radiother Oncol       Date:  2009-08-06       Impact factor: 6.280

6.  Metal artifact reduction in x-ray computed tomography (CT) by constrained optimization.

Authors:  Xiaomeng Zhang; Jing Wang; Lei Xing
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

Review 7.  Image-based brachytherapy for cervical cancer.

Authors:  John A Vargo; Sushil Beriwal
Journal:  World J Clin Oncol       Date:  2014-12-10

8.  Major clinical research advances in gynecologic cancer in 2012.

Authors:  Dong Hoon Suh; Jae-Weon Kim; Kidong Kim; Hak Jae Kim; Kyung-Hun Lee
Journal:  J Gynecol Oncol       Date:  2013-01-08       Impact factor: 4.401

9.  Dosimetric evaluation of rectum and bladder using image-based CT planning and orthogonal radiographs with ICRU 38 recommendations in intracavitary brachytherapy.

Authors:  Swamidas V Jamema; Sherly Saju; Umesh Mahantshetty; S Pallad; D D Deshpande; S K Shrivastava; K A Dinshaw
Journal:  J Med Phys       Date:  2008-01

10.  Comparison of conventional and CT-based planning for intracavitary brachytherapy for cervical cancer: target volume coverage and organs at risk doses.

Authors:  Cem Onal; Gungor Arslan; Erkan Topkan; Berrin Pehlivan; Melek Yavuz; Ezgi Oymak; Aydin Yavuz
Journal:  J Exp Clin Cancer Res       Date:  2009-07-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.