Arthur L R Souza1,2, Marcio A Correa1,2, Felipe Bohn2, Helder Castro1, Margarida M Fernandes1, Filipe Vaz1,3, Armando Ferreira1,3.
Abstract
Titanium-copper alloy films with stoichiometry given by Ti1-xCux were produced by magnetron co-sputtering technique and analyzed in order to explore the suitability of the films to be applied as resistive temperature sensors with antimicrobial properties. For that, the copper (Cu) amount in the films was varied by applying different DC currents to the source during the deposition in order to change the Cu concentration. As a result, the samples showed excellent thermoresistivity linearity and stability for temperatures in the range between room temperature to 110 °C. The sample concentration of Ti0.70Cu0.30 has better characteristics to act as RTD, especially the αTCR of 1990 ×10-6°C-1. The antimicrobial properties of the Ti1-xCux films were analyzed by exposing the films to the bacterias S. aureus and E. coli, and comparing them with bare Ti and Cu films that underwent the same protocol. The Ti1-xCux thin films showed bactericidal effects, by log10 reduction for both bacteria, irrespective of the Cu concentrations. As a test of concept, the selected sample was subjected to 160 h reacting to variations in ambient temperature, presenting results similar to a commercial temperature sensor. Therefore, these Ti1-xCux thin films become excellent antimicrobial candidates to act as temperature sensors in advanced coating systems.Entities:
Keywords: antimicrobial; temperature sensors; thin films; titanium-copper
Mesh:
Substances:
Year: 2022 PMID: 36236764 PMCID: PMC9570709 DOI: 10.3390/s22197665
Source DB: PubMed Journal: Sensors (Basel) ISSN: 1424-8220 Impact factor: 3.847
Figure 1Block diagram of the thermoresistive sensor readout circuit. At the top, the sample structure with the Titanium pads is depicted.
Figure 2(a) X-ray diffraction of produced thin films annealed at 250 C. The peaks are indexed through ICSD-43416 for Ti and ICSD-103128, ICSD-629379I, and CSD-107712 for TiCu. Representative tilted top-view SEM. micrographs for the samples prepared with (b) 5 mA, (c) 10, and (d) 15 mA.
Amount of Cu and Ti (at.%) present in the samples measured by EDS and the thickness of the thin films measured in the cross-section SEM micrographs.
| Ti | Cu | Ti (at.%) | Cu (at.%) | Ti | Thick. (nm) | Rough. (nm) |
|---|---|---|---|---|---|---|
| 200 | 5 | 0.74 | 0.26 | Ti | 46.6 | 4.8 |
| 200 | 10 | 0.70 | 0.30 | Ti | 39.4 | 8.0 |
| 200 | 15 | 0.54 | 0.46 | Ti | 53.9 | 6.5 |
Figure 3Antimicrobial activity of the materials against E. coli and S. aureus, measured in reduction of CFUs. The results represent three individual measurements.
Figure 4Fluorescence microscopy images of E. coli and S. aureus after 2 h in contact with the material. Live cells are represented in green and dead cells in red. (a,b) Results obtained for Ti film. (c,d) Results obtained for representative TiCu film. (e,f) Results for Cu film.
Figure 5(a) Electrical resistance measured under temperature cycles for the TiCu sample. (b) Electrical resistance stability for 50, 75, and 100 C for periods of 10 min for the TiCu sample.
Figure 6as a function of the temperature. The inset depicts the curve for TiCu sample before the annealing.
Figure 7(a) Temperature as a function of the time for commercial temperature sensor DHT11 response. (b) Temperature measurement with the developed TiCu thin film.