| Literature DB >> 36233423 |
Xiaotong Ren1, Jie Wang2, Xuemin Li1, Lingling Wu1.
Abstract
Our purpose is to evaluate long-term changes in corneal endothelial cells after Ex-PRESS shunt implantation for the treatment of glaucoma in Chinese patients by comparison with the contralateral eye. In this retrospective observational study, glaucoma patients with a single eye undergoing Ex-PRESS shunt implantation surgery were consecutively enrolled. For each patient, the clinical assessment, including corneal endothelial cell density (CECD) before surgery and at 6, 12 months, and at last follow-up (2.43 ± 0.63 years) after surgery was reviewed. The operated eyes were in the study group and the unoperated contralateral eyes were used as the control group to compare the CECD change. A total of 48 subjects (age, 51.02 ± 17.96 years) were included. The follow-up period was 2.08~3.17 years, with an average of 2.43 ± 0.63 years. At the last follow-up after the surgery, the CECD decrease in the operated eyes (5.0%) was similar to that in the contralateral eyes (3.2%) (p = 0.130). There were no significant differences in CECD reduction between the two groups at baseline and each postoperative follow-up (6 months, 12 months and at the last follow-up) (all p > 0.05). The average IOP reduction after the surgery was 50.8%, and the number of IOP-lowering medications was significantly reduced (p < 0.05). In addition, visual acuity showed no significant differences during follow-up (p > 0.05). In this study, we found that the CECD reduction of Ex-PRESS shunt-implanted Chinese eyes was similar to that of contralateral eyes without surgery.Entities:
Keywords: Ex-PRESS; contralateral eyes; corneal endothelial cell density (CECD); glaucoma; intraocular pressure (IOP); long-term
Year: 2022 PMID: 36233423 PMCID: PMC9572056 DOI: 10.3390/jcm11195555
Source DB: PubMed Journal: J Clin Med ISSN: 2077-0383 Impact factor: 4.964
Patients’ general information.
| Characteristics | Number |
|---|---|
| Sex (M/F) | 36/12 |
| Age at surgery (years) | 51.02 ± 17.96 |
| Diagnosis, Number of eyes (rate) | |
| Primary open-angle glaucoma | 42 (87.5%) |
| Secondary glaucoma | 6 (12.5%) |
| pigmentary glaucoma | 1 (2.1%) |
| angle-recession glaucoma | 5 (10.4%) |
| Preoperative IOP (mm Hg) | 27.42 ± 9.73 |
| Number of preoperative IOP-lowering medications | 2.79 ± 1.10 |
| Preoperative corneal endothelial cell density (cells/mm2) | 2427.69 ± 473.82 |
| The follow up period (years) | 2.43 ± 0.63 |
| Complete success eyes (rate) * | 35 (73.1%) |
| Qualified success eyes (rate) * | 44 (91.7%) |
Data are presented as numbers or means ± standard deviations. M: male; F: female; IOP = intraocular pressure. *: at the final follow-up (>2 years). Complete success was defined as IOP between 5 and 21 mm Hg without additional medications or/and procedures to reduce IOP, while the definition of qualified success was the same criteria mentioned above with or without medications. During the follow-up, 4 patients were undergone bleb needling for IOP elevation.
Changes in clinical parameters after Ex-PRESS implantation.
| Clinical Parameters | Baseline | 6 Months | 12 Months | Final Follow up (>2 Years) |
|---|---|---|---|---|
| N (eyes) | 48 | 42 | 32 | 48 |
| LogMAR BCVA | 0.45 ± 0.45 | 0.44 ± 0.39 | 0.42 ± 0.41 | 0.39 ± 0.36 |
|
| 0.564 | 0.577 | 0.169 | |
| IOP (mm Hg) | 27.42 ± 9.73 | 14.31 ± 3.43 | 14.16 ± 2.98 | 13.49 ± 2.62 |
|
| 0.000 | 0.000 | 0.000 | |
| medications | 2.79 ± 1.10 | 0.67 ± 1.00 | 0.71 ± 0.92 | 0.47 ± 0.69 |
|
| 0.000 | 0.000 | 0.000 |
Data are shown as the mean ± standard deviation. logMAR = logarithm of minimum angle of resolution; BCVA = best corrected visual acuity; IOP = intraocular pressure; medications: Number of preoperative IOP-lowering medications. p-valve: Compared to baseline (paired t test with Bonferroni correction). p values of less than 0.05 were considered statistically significant.
Comparison of CECD (cells/mm2) in Ex-PRESS implanted eyes and contralateral eyes.
| Follow-Up | N | Operated | Contralateral | |||
|---|---|---|---|---|---|---|
|
| 48 | 2427.69 ± 473.82 | 2536.16 ± 435.36 | 0.879 | ||
|
| 31 | 2407.70 ± 593.91 | 0.384 | 2475.94 ± 292.94 | 0.978 | 0.523 |
|
| 1.6 ± 12.6 | 1.0 ± 9.0 | 0.631 | |||
|
| 42 | 2364.28 ± 554.44 | 0.255 | 2417.18 ± 381.16 | 0.272 | 0.623 |
|
| 2.2 ± 8.1 | 1.8 ± 5.0 | 0.572 | |||
|
| 48 | 2316.70 ± 534.77 | 0.017 | 2401.47 ± 410.31 | 0.012 | 0.178 |
|
| 5.0 ± 12.2 | 3.2 ± 7.8 | 0.130 |
Data are shown as the mean ± standard deviation. Operated eyes: Ex-Press implantation eyes; Final: final follow up (>2 years); reduction (%): Percentage decrease in CECD from baseline. p a, p b: Compared to baseline (paired t test with Bonferroni correction). p c: Operation eyes vs. contralateral eyes (paired t test with Bonferroni correction). p values of less than 0.05 were considered statistically significant.