Literature DB >> 3578881

The effect of carbon monoxide inhalation on pulse oximetry and transcutaneous PO2.

S J Barker, K K Tremper.   

Abstract

Five dogs were anesthetized, intubated, and ventilated with various mixtures of oxygen, nitrogen, and carbon monoxide. Each dog was monitored with arterial and pulmonary artery catheters, a transcutaneous PO2 analyzer, and two pulse oximeters. An IL-282 Co-oximeter was used to periodically measure arterial oxyhemoglobin (O2Hb) and carboxyhemoglobin (COHb) as percentages of the total hemoglobin. The PaO2, PaCO2, and pHa were measured in the same blood specimens using standard electrodes. When the inspired oxygen concentration was reduced in the absence of COHb, the pulse oximeter saturation (SpO2) estimated O2Hb with reasonable accuracy. COHb levels were then varied slowly from 0-75% in each dog. As the COHb level increased and oxyhemoglobin decreased, both pulse oximeters continued to read an oxygen saturation of greater than 90%, while the actual O2Hb fell below 30%. In the presence of COHb, the SpO2 is approximately the sum of COHb and O2Hb, and, thus, may seriously overestimate O2Hb. The pulse oximeter, as the sole indicator of blood oxygenation, should, therefore, be used with caution in patients with recent carbon monoxide exposure. On the other hand, transcutaneous PO2 falls linearly as COHb increases, and reaches about one-fifth of its initial value at the highest COHb levels despite the maintenance of constant arterial PO2.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3578881     DOI: 10.1097/00000542-198705000-00014

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  36 in total

1.  Cigarette smoking behavior and respiratory alterations during sleep in a healthy population.

Authors:  Gonzalo G Casasola; José L Alvarez-Sala; José A Marques; José M F Sánchez-Alarcos; Donald P Tashkin; Domingo Espinós
Journal:  Sleep Breath       Date:  2002-03       Impact factor: 2.816

2.  Enamel nail polish does not interfere with pulse oximetry among normoxic volunteers.

Authors:  Thomas M Brand; Mary E Brand; Gregory D Jay
Journal:  J Clin Monit Comput       Date:  2002-02       Impact factor: 2.502

Review 3.  Emergency management of the airway outside the operating room.

Authors:  D L Bogdonoff; D J Stone
Journal:  Can J Anaesth       Date:  1992-12       Impact factor: 5.063

Review 4.  Pulse oximetry.

Authors:  J F Kelleher
Journal:  J Clin Monit       Date:  1989-01

Review 5.  [Inhalation injury--epidemiology, diagnosis and therapy].

Authors:  Ulrich Thaler; Paul Kraincuk; Lars-Peter Kamolz; Manfred Frey; Philipp G H Metnitz
Journal:  Wien Klin Wochenschr       Date:  2010-01       Impact factor: 1.704

Review 6.  Pulse oximetry and capnography in intensive and transitional care units.

Authors:  F Bongard; D Sue
Journal:  West J Med       Date:  1992-01

Review 7.  Interpretation of non-invasive oxygen and carbon dioxide data.

Authors:  K K Tremper
Journal:  Can J Anaesth       Date:  1990-05       Impact factor: 5.063

Review 8.  The Diagnosis and Treatment of Carbon Monoxide Poisoning.

Authors:  Lars Eichhorn; Marcus Thudium; Björn Jüttner
Journal:  Dtsch Arztebl Int       Date:  2018-12-24       Impact factor: 5.594

9.  Pulse oximetry at the roadside.

Authors: 
Journal:  BMJ       Date:  1989-04-22

Review 10.  [Air travel and respiratory diseases].

Authors:  Francisco García Río; Luis Borderías Clau; Ciro Casanova Macario; Bartolomé R Celli; Joan Escarrabill Sanglás; Nicolás González Mangado; Josep Roca Torrent; Fernando Uresandi Romero
Journal:  Arch Bronconeumol       Date:  2007-02       Impact factor: 4.872

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.